Single-phase autoreclosure of extra-high-voltage transmission lines. An investigation into the residual fault current and recovery voltage

Single-phase autoreclosure of extra-high-voltage transmission lines. An investigation into the residual fault current and recovery voltage

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Proceedings of the Institution of Electrical Engineers — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The success of single-phase autoreclosure of extra-high-voltage transmission lines is based on the possibility of self extinction of the secondary arc, in spite of the influence of the sound phases. The residual fault current and the recovery voltage of the switched phase are among the most essential factors affecting self extinction of the residual fault.In this paper, a method is developed for the calculation of the recovery voltage and residual fault current during single-pole switching. The power system investigated consists of a remote power station interconnected to a large electrical system, through a single-circuit extra-high-voltage transmission line. The analysis includes the effect of fault location, line length, station parameters, transmission-line loading and the electromechanical swing subsequent to fault occurrence. The effects of the above factors on recovery voltage and residual current are investigated on the basis of numerical computations for a 500 kV transmission system.

References

    1. 1)
      • E. Maury . L'extinction des arcs dans le réenclenchement ultrarapide monophase sur les lignes à 220kV. Rev. Gén. Élect. , 5 , 79 - 90
    2. 2)
      • P.H. Sporn , D.C. Prince . Ultra-high-speed reclosing of highvoltage transmission lines. Trans. Amer. Inst. Elect. Engrs. , 81 - 90
    3. 3)
      • L. Norlin . Single-phase high-speed reclosing tests in the Swedish 220kV network. Tekn. Tidskrift
    4. 4)
      • L. Norlin . High-speed reclosure of high-voltage circuit breakers. Tekn. Tidskrift , 177 - 180
    5. 5)
      • E.W. Kimbark . Suppression of ground-fault arcs on single-pole switched e.h.v. lines by shunt reactors. IEEE Trans. , 285 - 290
    6. 6)
      • A.C. Boisseau , B.W. Wyman , W.F. Skeats . Insulator flashoyer deionisation time as a factor in applying high-speed reclosing circuit breakers. Trans. Amer. Inst. Elect. Engrs. , 1058 - 1066
    7. 7)
      • V.A. Venikov . (1964) , Transient electromechanical processes in electrical systems.
    8. 8)
      • A.S. Majkopar . Minimum time of automatic reclosing. Elect. Technol., USSR , 302 - 315
    9. 9)
      • Knudsen, N.: `Single-phase switching of transmission lines using reactors for extinction of the secondary arc', 310, Report, 1962.
    10. 10)
      • Jahn, D., Koettnitz, H., Schulze, H.: `Earth wires as a means of improving single-pole rapid reclosing of long high-voltage lines', 401, Report, 1964, p. 1964, ibid..
http://iet.metastore.ingenta.com/content/journals/10.1049/piee.1969.0017
Loading

Related content

content/journals/10.1049/piee.1969.0017
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address