The calculation of cyclic rating factors and emergency loading for one or more cables laid direct or in ducts

The calculation of cyclic rating factors and emergency loading for one or more cables laid direct or in ducts

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Proceedings of the IEE - Part C: Monographs — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The knowledge of the loss load factor of a load cyclically applied to a cable laid direct in the ground or in a duct, together with the detail of the load current for the six hours prior to maximum core temperature, is shown to be adequate for cyclic-rating-factor calculations. If the loss load factor is known without further calculation, the method is shorter than an earlier one described by the author. The method is extended to deal with short-term emergency loads within accepted temperature limits and with groups of cables carrying diverse cyclic loads.

References

    1. 1)
      • Goldenberg, H.: `The Calculation of Cyclic Rating Factors for Cables Laid Direct or in Ducts', Monograph No. 203 S, Proceedings I.E.E., October 1956, 104 C, p. 154.
    2. 2)
      • Goldenberg, H.: `A Further Simple Method for the Calculation of Cyclic Rating Factors and Emergency Loading for Cables Laid Direct or in Ducts', Ref. F/T190, E.R.A. Report, 1957.
    3. 3)
      • S. Whitehead , E.E. Hutchings . Current Rating of Cables for Transmission and Distribution. Journal, I.E.E.
    4. 4)
      • F.H. Buller . Thermal Transients on Buried Cables. Transactions of the American I.E.E.
    5. 5)
      • : Ref. F/T12, Supplement to Report, 1925, on the Heating of Buried Cables (E.R.A. Report Ref. F/T15).
    6. 6)
      • (1940) Tables of Sine, Cosine and Exponential Integrals.
    7. 7)
      • Goldenberg, H.: `The Calculation of External Thermal Resistance and Cyclic Rating Factors for Groups of Cables Laid Direct in the Ground or in Ducts', Ref. F/T192, E.R.A.Report, 1957.