Automatic circuit reclosers

Access Full Text

Automatic circuit reclosers

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Proceedings of the IEE - Part A: Power Engineering — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Of recent years there has been a large increase in the use and application of electricity in rural areas. The loads are usually small but are distributed over very large areas, and a high standard of service is an essential requirement as prolonged interruption of supply may cause serious inconvenience to users.Supplies in such areas are generally provided by high-voltage overhead lines, from which distribution transformers provide links with the general medium-voltage distribution networks. The transformers and spur h.v. lines are usually protected by fuses, with the number of h.v. circuit-breakers kept to a minimum. Under these conditions, therefore, h.v. faults of both a transient and a permanent nature might cause prolonged interruption of supply, owing to the distances to be covered before fuses can be replaced or circuit-breakers reclosed.Where only a limited breaking capacity is required an automatic circuit recloser can be made to overcome the operational difficulties detailed above. The paper reviews some of the factors influencing the design, selection and application of circuit reclosers. The principles determining whether the main contacts of a recloser are to “lock open” or “hold closed” upon the completion of an operating sequence are discussed, and the co-ordination of reclosers with other reclosers and with fuses is described.The development of the use of automatic-reclosing features is also discussed in relation to operation in conjunction with automatic sectionalizers.

Inspec keywords: oil circuit breakers

Subjects: Switchgear

http://iet.metastore.ingenta.com/content/journals/10.1049/pi-a.1955.0156
Loading

Related content

content/journals/10.1049/pi-a.1955.0156
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Comment
A comment has been published for this article:
Discussion on “Automatic circuit reclosers” before the Supply Section, 27th April, 1955
Comment
A comment has been published for this article:
Discussion on “Automatic circuit reclosers”
Correspondence
This article has following corresponding article(s):
Automatic circuit reclosers