The measurement of permitivity and power factor of dielectrics at frequencies from 300 to 600 Mc/s

Access Full Text

The measurement of permitivity and power factor of dielectrics at frequencies from 300 to 600 Mc/s

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Proceedings of the IEE - Part III: Radio and Communication Engineering — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The paper describes a resonance method of measuring permittivity and power factor which is essentially a development of the Hartshorn and Ward apparatus, suitable for use at the higher frequencies. The method is one of capacitance variation, and the disc form of sample, the circular plate electrodes and the cylindrical form of micrometer capacitor are retained but reduced in linear dimensions. The capacitive elements are mounted in a re-entrant cavity, and the micrometer capacitor is so placed that the voltage across it is only a fraction of that across the plate electrodes; this increases the fineness of adjustment. The micrometer capacitor can be calibrated only by using the cavity as a wavemeter; the capacitance settings were therefore expressed in terms of the corresponding resonance frequencies, and the calculations of power factor then became identical in form with those of the frequency-change method, although the measurements were made at a constant frequency. After applying the appropriate corrections the permittivity can be determined to within ± 1% over most of the range. The high Q-factor of the cavity and the precision of adjustment of the micrometer capacitor make the power-factor determinations highly accurate. For values less than about 0.01 the error is estimated as being less than ± 2 × 10−5 (for measurements on solids). For higher values a superheterodyne receiver incorporating a piston attenuator is used as the detector, and the estimated limits of error for such measurements are ± 5 × 10−4.

Inspec keywords: insulating materials; power factor measurement; permittivity measurement

Subjects: Dielectric variables measurement; Insulation and insulating coatings

References

    1. 1)
      • W.L. Barrow , W.W. Mieher . Natural Oscillations of Electrical Cavity Resonators. Proceedings of the Institute of Radio Engineers
    2. 2)
      • L. Hartshorn , W.H. Ward . The Measurement of Permittivity and Power Factor of Dielectrics at Frequencies from 104 to 108 cycles per second. Journal I.E.E.
    3. 3)
      • C.N. Works . Resonant Cavities for Dielectric Measurements. Journal of Applied Physics
    4. 4)
      • F. Horner , T.A. Taylor , R. Dunsmuir , I. Lamb , Willis Jackson . Resonance Methods of Dielectric Measurement at Centimetre Wavelengths. Journal I.E.E.
    5. 5)
      • S.I. Reynolds . Improved Re-entrant Cavity. General Electric Review
http://iet.metastore.ingenta.com/content/journals/10.1049/pi-3.1951.0062
Loading

Related content

content/journals/10.1049/pi-3.1951.0062
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Correspondence
This article has following corresponding article(s):
The measurement of permittivity and power factor of dielectrics at frequencies from 300 to 600 Mc/s