Energy storage systems (ESS) and microgrids in Brittany islands
- Author(s): Gilles Lancel 1 ; Boris Deneuville 2 ; Camille Zakhour 1 ; Etienne Radvanyi 1 ; Julien Lhermenault 1 ; Caroline Ducharme 3 ; Sébastien Ruiz 3
-
-
View affiliations
-
Affiliations:
1:
EDF R&D – LME , Moret-sur-Loing, France ;
2: EDF R&D – MIRE , Palaiseau, France ;
3: EDF SEI , Paris, France
-
Affiliations:
1:
EDF R&D – LME , Moret-sur-Loing, France ;
- Source:
Volume 2017, Issue 1,
October
2017,
p.
1741 – 1744
DOI: 10.1049/oap-cired.2017.1188 , Online ISSN 2515-0855
Full text loading...
Inspec keywords: power generation planning; power generation reliability; energy storage; photovoltaic power systems; environmental factors; power system stability; research and development; power generation economics; power grids; distributed power generation; power consumption; power system security; power generation protection
Other keywords: microgrids; energy storage systems; Sein Island; PV generation; diesel generators; simulation tool; PV consumption; photovoltaic power; greenhouse gas emissions; quality-of-service; electricity generation cost; environmental impact; RE deployment; Brittany islands; control algorithms; generation means failures; autonomous network; French regulatory framework; renewable energy intermittency; EDF R&D; protection plan; PV installation; renewable energies; ESS sizing; ESS power conversion system; gensets features; isolated network; grid security; power system stability
Subjects: Power system protection; Solar power stations and photovoltaic power systems; Power system planning and layout; Reliability; Environmental factors; Distributed power generation; Power system management, operation and economics
References
-
-
1)
-
1. Fabien, L.: ‘Primary frequency control by using a 1 MW battery: study at grid scale on the concept grid EDF platform’, CIRED paper 0775, Lyon, 2015.
-
-
2)
-
5. Pan, Y.: ‘Impact of inverter interfaced distributed generation on overcurrent protection in distribution systems’. IEEE Power Engineering and Automation Conf., 2011.
-
-
3)
-
2. EDF, 2015. Available at www.edf.com, accessed on 15th January 2017.
-
-
4)
-
13. Nimpitiwan, N., Heydt, G.T., Ayyanar, R., et al: ‘fault current contribution from synchronous machine and inverter based distributed generators’, IEEE Trans. Power Deliv., 2007, 22, (1), pp. 634–641 (doi: 10.1109/TPWRD.2006.881440).
-
-
5)
-
4. Multon, B.: ‘Ressources énergétiques et solutions pour l'alimentation en électricité des populations isolées’ (Electrotechnique du Futur, Belfort, 2011).
-
-
6)
-
7. International Standard IEC 60909: ‘Short-circuit current in three phase a.c. systems’, 2002.
-
-
7)
-
3. Gondal, A., Davis, F.A., Eyre, T.S.: ‘Bore polish’, Mater. Sci. Technol., 1998, 14, (11), pp. 67–72.
-
-
1)