Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free Improvement of the microcapacitive humidity sensor by the package optimisation

To achieve good properties such as the hysteresis, repeatability, stability, linearity and response time in this work, the optimisation processes of the package are presented for a microcapacitive humidity sensor. On the basis of theoretical analysis, the optimisation will be conducted in two ways, including reducing the effect of parasitic capacitance in the microcapacitive humidity sensor measurement system and decreasing the adsorption of water molecules on the package surface. The reduction of the influence of parasitic capacitance was realised by reasonably designing the PCB and the isolation package. The decrease of water adsorption on the package surface was achieved by coating a layer of hydrophobic material. The experimental results proved that the package optimisation enables the humidity sensor with better performance; for instance the hysteresis error is more than six times lower, the repeatability error is more than ten times lower, and the temperature drift is about two times lower, and the linear fitting error is three times lower than the pre-optimised humidity sensor. Especially, the humidity response time in both adsorption and desorption is extremely improved.

References

    1. 1)
    2. 2)
    3. 3)
    4. 4)
      • 11. Laconte, J., Wilmart, V., Flandre, D., et al: ‘High-sensitivity capacitive humidity sensor using 3-layer patterned polyimide sensing film’. SENSORS, 2003 IEEE, Toronto, Ont., 2003, pp. 372377.
    5. 5)
    6. 6)
    7. 7)
      • 10. Liu, J., Du, L., Pan, Y., et al: ‘Reducing the effect of parasitic capacitance on the micro-capacitive humidity sensor’. Proc. of the 14th Annual IEEE Int. Conf. on Nano/Micro Engineered and Molecular Systems, Bangkok, Thailand, 11–14 April 2019, pp. 494497.
    8. 8)
      • 3. Wernecke, R., Wernecke, J.: ‘Industrial moisture and humidity measurement: a practical guide’ (Wiley, New Jersey, USA, 2014).
    9. 9)
      • 5. Starke, E., Turke, A., Krause, M., et al: ‘Flexible polymer humidity sensor fabricated by inkjet printing Technische Universität Dresden’. 2011 16th Int. Institute of Semiconductors and Microsystems, 01062 Dresden, Germany'Solid-State Sensors, Actuators Microsystems Conf. (TRANSDUCERS), Beijing, People's Republic of China, 2011, pp. 11521155.
    10. 10)
    11. 11)
      • 1. Mason, A., Yazdi, N., Najafi, K., et al: ‘A low-power wireless microinstrumentation system for environmental monitoring’, Stockholm, Sweden, 1995, pp. 107110.
    12. 12)
    13. 13)
http://iet.metastore.ingenta.com/content/journals/10.1049/mnl.2019.0422
Loading

Related content

content/journals/10.1049/mnl.2019.0422
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address