Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Calibrated micropost arrays for biomechanical characterisation of cardiomyocytes

Calibrated micropost arrays for biomechanical characterisation of cardiomyocytes

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Micro & Nano Letters — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The study of biomechanics of isolated cardiomyocytes can allow us to understand the cardiac function and disease development in the absence of viscoelastic or contractile properties of the surrounding tissue. However, popular techniques such as micropipettes and carbon fibre-based measurements require serial, single-cell measurements and limit the amount of data passing through a system or process. The authors utilise elastomer micropost arrays microfabricated by a replica molding technique for precise and quantitative force measurements of cardiomyocytes with the potential for high throughput. The authors also present a calibration system using a piezoresistive force sensor and video-analysis technique to improve the resolution and validate the analysis of these low-force measurements. Calibrated microposts arrays are applied to measure the contractile forces of rat neonatal cardiomyocytes. Using image processing, the contractile forces for a sample of cardiomyocytes are extracted. It was found that isolated rat neonatal myocytes generate 39±5 nN average contractile force per post and an integrated axial contractile force of 189±20 nN, which is four times smaller than isolated adult Wistar rat cardiomyocytes and 30 times smaller than isolated adult rat cardiomyocytes. With calibration and quantitative image analysis, this study demonstrates that micropost systems can provide precise high-throughput test beds for myocyte mechanics using pharmacologic, small peptide, gene therapies or heart disease models.

References

    1. 1)
    2. 2)
    3. 3)
    4. 4)
      • J.E. Mark . (1999) Polymer data handbook.
    5. 5)
    6. 6)
    7. 7)
    8. 8)
    9. 9)
      • A. Araujo , J.W. Walker . Kinetics of tension development in skinned cardiac myocytes measured by photorelease of Ca2+. Am. J. Physiol. Heart Circ. Physiol. , 5 , H1643 - H1653
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
    16. 16)
    17. 17)
    18. 18)
      • Armani, D., Liu, C., Aluru, N.: `Re-configurable fluid circuits by PDMS elastomer micromachining', 12thIEEE Int. Conf. on Micro Electro Mechanical Systems, 1999.
    19. 19)
    20. 20)
    21. 21)
    22. 22)
      • S.I. Yasuda , S. Sugiura , N. Kobayakawa . A novel method to study contraction characteristics of a single cardiac myocyte using carbon fibers. Am. J. Physiol. Heart Circ. Physiol. , 3 , H1442 - H1446
    23. 23)
    24. 24)
    25. 25)
      • C. Tasche , E. Meyhofer , B. Brenner . A force transducer for measuring mechanical properties of single cardiac myocytes. Am. J. Physiol. , H2400 - H2408
    26. 26)
    27. 27)
      • P. Ferdinand . (2002) Mechanics of materials.
    28. 28)
    29. 29)
    30. 30)
    31. 31)
      • J.P. Holman . (2001) Experimental methods for engineers.
    32. 32)
    33. 33)
http://iet.metastore.ingenta.com/content/journals/10.1049/mnl.2011.0031
Loading

Related content

content/journals/10.1049/mnl.2011.0031
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address