Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon openaccess Simulation and measurement of spectra of reference filtered X radiation

The energy spectrum is one of the most effective methods to characterise the quality of reference filtered X radiations. To obtain the energy resolution, the authors choose seven sealed standard radioactive sources to carry out energy calibration for high-purity germanium detector whose energy resolution is within 3%. Then they use this spectrometer to measure the reference filtered X radiations with its energy from 55 to 125 keV of low air-kerma rate series, meanwhile the BEAMnrc is used to simulate the spectra of the same four radiation qualities. By analysing the data of spectral distribution, they can determine mean energy and spectral resolution of these reference radiation qualities. By comparing simulation results with actual measurements, the result shows the spectra stimulated by the BEAMnrc are consistent with the spectra measured by high-purity germanium detector and the deviation of the mean energy is within 4.0%. The spectral resolution of the reference filtered X radiation is 22.8, 22.4, 22.5 and 22.8%, respectively.

References

    1. 1)
      • 4. International Organization for Standardization: ‘X and gamma reference radiation for calibrating dose meters and dose rate meters and for determining their response as a function of photon energy. Part 4: Calibration of area and personal dose meters in low energy X reference radiation fields’, ISO4037-4, 2004.
    2. 2)
      • 9. Nikl, M.: ‘Scintillation detectors for x-rays’, Meas. Sci. Technol., 2006, 17, (4), pp. 3754.
    3. 3)
      • 15. Ma, C.M., Rogers, D.W.O.: ‘BEAMDP users manual’, (Nrc Report Pirs 2009), pp. 1619.
    4. 4)
      • 13. Rogers, D.W.O., Walters, B.R.B., Kawrakow, I.: ‘BEAMnrc users manual’, (Nrc Report Pirs 2011), pp. 1876.
    5. 5)
      • 11. D'Alberti, F., Forte, M.: ‘Calibration of a HPGe detector for in-situ gamma spectrometry: a comparison between a Monte Carlo based code and an experimental method’, Radioact. Environ., 2005, 7, (4), pp. 198206.
    6. 6)
      • 7. Boone, J.M., Burkett, G.W., Mckenney, S.E.: ‘Apparatus and methods for determination of the half value layer of X-ray beams’, US Patent 9,008,264 B2, April 2015.
    7. 7)
      • 8. Kimura, M.: ‘Gas detector’, United States Patent 4,343,768, August 1982.
    8. 8)
      • 3. International Organization for Standardization: ‘X and gamma reference radiation for calibrating dose meters and dose rate meters and for determining their response as a function of photon energy. Part 3: Calibration of area and personal dose meters and the measurement of their response as a function of energy and angle of incidence’, ISO4037-3, 1999.
    9. 9)
      • 12. Kawrakow, I., Rogers, D.W.O.: ‘The EGSnrc code system: Monte Carlo simulation of electron and photon transport’, (Nrc Report Pirs 2011), pp. 28106.
    10. 10)
      • 2. International Organization for Standardization: ‘X and gamma reference radiation for calibrating dose meters and dose rate meters and for determining their response as a function of photon energy. Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1.3 and 4 MeV to 9 MeV’, ISO4037-2, 1997.
    11. 11)
      • 1. International Organization for Standardization: ‘X and gamma reference radiation for calibrating dose meters and dose rate meters and for determining their response as a function of photon energy. Part 1: Radiation characteristics and production methods’, ISO4037-1, 1996.
    12. 12)
      • 6. Trout, E.D., Kelley, J.P., Lucas, A.C.: ‘Determination of half-value layer’, Am. J. Roentgenology Radium Ther. Nucl. Med., 1960, 84, (1), p. 729.
    13. 13)
      • 5. Zhang, Q.L., Han, M., Huang, Y., et al: ‘Establishment of filtered X-ray reference radiation based on ISO4037-1:1996 in CIRP’, J. Nucl. Sci. Technol., 2008, 45, (sup5), pp. 278281.
    14. 14)
      • 14. Rogers, D.W., Faddegon, B.A., Ding, G.X., et al: ‘BEAM: a Monte Carlo code to simulate radiotherapy therapy units’, Med. Phys., 1995, 22, (5), pp. 503524.
    15. 15)
      • 10. Shahar, A., Ei-Hanany, U., Tsigelman, A., et al: ‘Semiconductor detector’, US Patent 5,905,264, May 1999.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.9088
Loading

Related content

content/journals/10.1049/joe.2018.9088
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address