Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon openaccess System study of pneumatic exoskeleton rehabilitation manipulator

In this study, biological characteristic of manpower is analysed and then the structural of exoskeleton rehabilitation manipulator is designed base on the thought of modular. First, the overall assembly drawing is drawn by SolidWorks. Second, the controlled pneumatic system is designed. The mainly contents are selecting mini pneumatic cylinder as a driver and controlling electromagnetic reversing valve which can lead to the piston movement of cylinder by STM32F429 microcontroller. At last, the movement simulation of exoskeleton rehabilitation manipulator is done and analysed by ADAMS, and then the experimental research of the same move pattern with simulation is carried out. It is proved that the pneumatic exoskeleton rehabilitation manipulator system has certain reliability and feasibility. Furthermore, it has the ability to meet the rehabilitation needs of patients with finger movement disorders.

References

    1. 1)
      • 1. Krebs, H.I., Palazzolo, J.J., Dipietro, L., et al: ‘Rehabilitation robotics: performance-based progressive robot-assisted therapy’, Auton. Robots, 2003, 15, (1), pp. 720.
    2. 2)
      • 10. Weiss, P., Heyer, L., Munte, T.F., et al: ‘Towards a parameterizable exoskeleton for training of hand function after stroke’. 2013 IEEE Int. Conf. Rehabilitation Robotics, USA, 2013.
    3. 3)
      • 5. Bae, J.H., Kim, Y.M., Moon, I.: ‘Wearable hand rehabilitation robot capable of hand function assistance in stroke survivors’. The Fourth IEEE RAS/EMBS Int. Conf. Biomedical Robotics and Biomechatronics, Italy, 2012.
    4. 4)
      • 9. Fu, Y.L., Zhang, F.X., Ma, X., et al: ‘Development of a CPM machine for injured fingers’. Engineering in Medicine and Biology 27th Annual Conf., China, 2005, 5, pp. 50175020.
    5. 5)
      • 6. Bi, Q., Yang, C.J., Deng, X.L., et al: ‘Contacting mechanical impedance of human finger based on uncertain system’. 2013 IEEE/ASME Int. Conf. Advanced Intelligent Mechatronics, Australia, 2013, pp. 16191624.
    6. 6)
      • 4. Kim, Y.M., Jung, S.Y., Moon, I.: ‘Design of a wearable upper-limb rehabilitation robot using parallel mechanism’. ICROS-SICE Int. Joint Conf., Japan, 2009, pp. 785789.
    7. 7)
      • 2. Gan, Z.K.: ‘Design and research of electric and control system for a hand’, PhD thesis, Harbin Institute of Technology, 2011.
    8. 8)
      • 7. Faraz, A., Payanceh, S.: ‘A robotic case study: optimal design for laparoscopic positioning stands’, IEEE Int. Conf. Robot. Autom., 1998, 17, (9), pp. 15531560.
    9. 9)
      • 8. Sun, Z.S., Miao, X.D., Li, X.N.: ‘Design of a bidirectional force feedback dataglove based on pneumatic artificial muscles’. Proc. 2009 IEEE Int. Conf. Mechatronics and Automation, China, 2009, pp. 17671771.
    10. 10)
      • 13. Hagert, C.G.: ‘Anatomical aspects on the design of metacarpophalangeal implants’, Reconstr Stug Traumatol, 1981, 18, pp. 92110.
    11. 11)
      • 3. Dollar, A.M., Herr, H.: ‘Lower extremity exoskeletons and active orthoses: challenges and state-of-the-art’, IEEE Trans. Robot., 2008, 24, (1), pp. 144158.
    12. 12)
      • 12. Kuang, S.C., Guo, X.: ‘Musculoskeletal system basic biomechanics’ (People's Health Press, 2008, 3rd edn.).
    13. 13)
      • 11. Capener, N.: ‘The hand in surgery’, J. Bone Joint Surg. Brit. Volume, 1956, 38-B, (1), p. 128.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.9005
Loading

Related content

content/journals/10.1049/joe.2018.9005
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address