http://iet.metastore.ingenta.com
1887

access icon openaccess System study of pneumatic exoskeleton rehabilitation manipulator

  • XML
    34.7021484375Kb
  • HTML
    39.7939453125Kb
  • PDF
    3.8394527435302734MB
Loading full text...

Full text loading...

/deliver/fulltext/10.1049/joe.2018.9005/JOE.2018.9005.html;jsessionid=4lhipo5d7a453.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.9005&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Krebs, H.I., Palazzolo, J.J., Dipietro, L., et al: ‘Rehabilitation robotics: performance-based progressive robot-assisted therapy’, Auton. Robots, 2003, 15, (1), pp. 720.
    2. 2)
      • 2. Gan, Z.K.: ‘Design and research of electric and control system for a hand’, PhD thesis, Harbin Institute of Technology, 2011.
    3. 3)
      • 3. Dollar, A.M., Herr, H.: ‘Lower extremity exoskeletons and active orthoses: challenges and state-of-the-art’, IEEE Trans. Robot., 2008, 24, (1), pp. 144158.
    4. 4)
      • 4. Kim, Y.M., Jung, S.Y., Moon, I.: ‘Design of a wearable upper-limb rehabilitation robot using parallel mechanism’. ICROS-SICE Int. Joint Conf., Japan, 2009, pp. 785789.
    5. 5)
      • 5. Bae, J.H., Kim, Y.M., Moon, I.: ‘Wearable hand rehabilitation robot capable of hand function assistance in stroke survivors’. The Fourth IEEE RAS/EMBS Int. Conf. Biomedical Robotics and Biomechatronics, Italy, 2012.
    6. 6)
      • 6. Bi, Q., Yang, C.J., Deng, X.L., et al: ‘Contacting mechanical impedance of human finger based on uncertain system’. 2013 IEEE/ASME Int. Conf. Advanced Intelligent Mechatronics, Australia, 2013, pp. 16191624.
    7. 7)
      • 7. Faraz, A., Payanceh, S.: ‘A robotic case study: optimal design for laparoscopic positioning stands’, IEEE Int. Conf. Robot. Autom., 1998, 17, (9), pp. 15531560.
    8. 8)
      • 8. Sun, Z.S., Miao, X.D., Li, X.N.: ‘Design of a bidirectional force feedback dataglove based on pneumatic artificial muscles’. Proc. 2009 IEEE Int. Conf. Mechatronics and Automation, China, 2009, pp. 17671771.
    9. 9)
      • 9. Fu, Y.L., Zhang, F.X., Ma, X., et al: ‘Development of a CPM machine for injured fingers’. Engineering in Medicine and Biology 27th Annual Conf., China, 2005, 5, pp. 50175020.
    10. 10)
      • 10. Weiss, P., Heyer, L., Munte, T.F., et al: ‘Towards a parameterizable exoskeleton for training of hand function after stroke’. 2013 IEEE Int. Conf. Rehabilitation Robotics, USA, 2013.
    11. 11)
      • 11. Capener, N.: ‘The hand in surgery’, J. Bone Joint Surg. Brit. Volume, 1956, 38-B, (1), p. 128.
    12. 12)
      • 12. Kuang, S.C., Guo, X.: ‘Musculoskeletal system basic biomechanics’ (People's Health Press, 2008, 3rd edn.).
    13. 13)
      • 13. Hagert, C.G.: ‘Anatomical aspects on the design of metacarpophalangeal implants’, Reconstr Stug Traumatol, 1981, 18, pp. 92110.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.9005
Loading

Related content

content/journals/10.1049/joe.2018.9005
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address