access icon openaccess Influence factors and reasonable arrangement of corridor width of ±800 kV HVDC and 750 kV HVAC hybrid transmission lines

Loading full text...

Full text loading...

/deliver/fulltext/joe/2019/16/JOE.2018.8901.html;jsessionid=27knniynfsmsi.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.8901&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Cui, X., Zhou, X., Lu, T.: ‘Recent progress in the calculation methods of ion flow field of HVDC transmission lines’, Proc. CSEE, 2012, 32, (36), pp. 130141.
    2. 2)
      • 2. Maruvada, P. S., Drogi, S.: ‘Field and ion interactions of hybrid AC/DC transmission lines’, IEEE Trans. Power Deliv., 1988, 3, (3), pp. 11651172.
    3. 3)
      • 3. Zhao, T., Sebo, S. A., Kasten, D. G.: ‘Calculation of single phase AC and monopolar DC hybrid corona effects’, IEEE Trans. Power Deliv., 1996, 11, (3), pp. 14541463.
    4. 4)
      • 4. Yin, H., He, J., Zhang, B., et al: ‘Finite volume-based approach for the hybrid ion-flow field of UHVAC and UHVDC transmission lines in parallel’, IEEE Trans. Power Deliv., 2011, 26, (4), pp. 28092820.
    5. 5)
      • 5. Lu, T., Zhou, X., Li, J., et al: ‘Prediction of ground level electric field and ion current density under three-circuit HVAC/HVDC transmission lines on one tower’, Power Syst. Technol., 2012, 36, (5), pp. 610.
    6. 6)
      • 6. Straumann, U., Franck, C. M.: ‘Ion-flow field calculations of AC/DC hybrid transmission lines’, IEEE Trans. Power Deliv., 2013, 28, (1), pp. 294302.
    7. 7)
      • 7. Zhou, X., Lu, T., Cui, X., et al: ‘Corona loss analysis of high voltage DC transmission lines in close proximity of high voltage AC transmission lines’, Proc. CSEE, 2011, 31, (31), pp. 211218.
    8. 8)
      • 8. Zhao, Y., Zhang, W.: ‘Research on hybrid electric field caused by HVAC and HVDC transmission lines erected on the same tower’, Power Syst. Technol., 2012, 38, (11), pp. 37223727.
    9. 9)
      • 9. Yong, Y., Jia-Yu, L. U., Yong, J. U.: ‘Study on the hybrid electric field over the ground surface under AC lines and ±800 kV DC lines in the same corridor’, Power Syst. Technol., 2009, 33, (15), pp. 5459.
    10. 10)
      • 10. Gui-Fang, W. U., Yuan, C. F., Jia-Yu, L. U., et al: ‘Calculation on electromagnetic environment of UHVDC and EHVAC transmission lines erected in a common corridor’, Power Syst. Technol., 2010, 34, (2), pp. 1419.
    11. 11)
      • 11. Maruvada, P. S.: ‘Corona performance of high-voltage transmission lines’ (Research Studies Press, Johannesburg, South Africa, 2000).