access icon openaccess Research on optimisation of minimum air clearance of 1000 kV UHV AC substation

  • XML
    71.97265625Kb
  • PDF
    1.3315181732177734MB
  • HTML
    86.6962890625Kb
Loading full text...

Full text loading...

/deliver/fulltext/10.1049/joe.2018.8806/JOE.2018.8806.html;jsessionid=1unqo76pljchd.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.8806&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Zhenya, L.: ‘Overvoltage and insulation coordination of UHV AC transmission system’ (China Electric Power Press, Beijing, China, 2008), pp. 7380.
    2. 2)
      • 2. GB/Z 24842–2009: ‘Overvoltage and insulation coordination of 1000 kV UHV AC transmission project’. 2009.
    3. 3)
      • 3. Peihong, Z., Huiwen, H.: ‘Calculation and analysis of switching overvoltage front time and switching impulse insulation coordination for UHV AC transmission line of Chinese pilot project and double-circuit project’, High Volt. Eng., 2014, 40, (6), pp. 17811794.
    4. 4)
      • 4. Huiwen, H., Dingxie, G., Peihong, Z., et al: ‘Simulating calculation and analysis of time-to-crest of switching impulse test voltage of Chinese UHV AC pilot and demonstration project’, High Volt. Eng., 2011, 37, (9), pp. 21562162.
    5. 5)
      • 5. Zhenqiang, L., Peihong, Z., Ying, L., et al: ‘Feasibility research on cancelling breaker closing resistor of UHV transmission lines’, High Volt. Eng., 2015, 41, (11), pp. 37213726.
    6. 6)
      • 6. Liang, X., Qiming, Y., Xiaoqing, L., et al: ‘Phase-to-phase switching impulse discharge characteristics of UHVAC series compensation’, High Volt. Eng., 2016, 42, (2), pp. 551556.
    7. 7)
      • 7. Qiming, Y., Liang, X., Xiaoqing, L., et al: ‘Test research on phase-to-ground air-gap discharge characteristics of UHV substation’, Appl. Mech. Mater., 2014, 2947, (492), pp. 162168.
    8. 8)
      • 8. Shuchun, D.: ‘Selection of clearances for UHVAC overhead transmission line in China’, Electr. Power, 2006, 39, (10), pp. 5254.
    9. 9)
      • 9. Peiguo, L., Weiming, L., Yinmei, Y., et al: ‘Calculation of insulation coordination of HVDC transmission line tower with the statistical method’, Power Syst. Technol., 1992, 4, pp. 3136.
    10. 10)
      • 10. Fei, S.: ‘Insulation coordination of UHV transmission system’ (Zhejiang University, Hangzhou, 2012), p. 2.
    11. 11)
      • 11. GB/T 311.2–2013: ‘Insulation co-ordination – part 2: application guide’. 2013.
    12. 12)
      • 12. Yanyan, H., Liangjin, C., Wei, S.: ‘Statistical calculation of switching overvoltage in 750 kV power transmission systems’, High Volt. Eng., 2004, 30, (8), pp. 68.
    13. 13)
      • 13. Jian, S., Libo, Q.: ‘Study of restricting switching overvoltage of 750 kV system with circuit breaker closing resistor’, J. Shaanxi Univ. Technol. (Natural Sc. Edition), 2012, 28, (3), pp. 1014.
    14. 14)
      • 14. Huiwen, H., Lei, W., Zhenqiang, L., et al: ‘Insulation level optimization of UHV power transmission system’ (China Electric Power Research Institute, Wuhan, China, 2015).