Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon openaccess Distance protection and fault location of the PV power plants distribution lines

Unlike the synchronous generators, the short-circuit current provided by the photovoltaic (PV) sources is limited by the grid-connected inverters and closely related to the normal conditions, which impacts the protection of the power systems. This study deals with the protection of the power lines (distribution feeders) that connect the PV power plants (PVPP) to the grid; the first part of this study analyses the impact of the grid-connected PV (GCPV) system on the conventional distance protection. A specific coordination between the over-current protection of the grid side and the distance protection of the PVPP side was used to eliminate this impact. This coordination requires delaying the distance protection and keeping the inverter connected to the grid, which was achieved by fault ride-through (FRT) feature accompanied with the inverter control during the fault condition. The second part studies the possibility of using the double-end-impedance-based fault location on the PVPP power lines, and some FRT strategies were suggested to reduce the effect of the inverter control loops on obtaining the accurate fault location. The proposed work was verified by GCPV system model using MATLAB/Simulink software.

References

    1. 1)
      • 15. Alepuz, S., Busquets-Monge, S., Josep, B., et al: ‘Control strategies based on symmetrical components for grid-connected converters under voltage dips’, IEEE Trans. Ind. Electron., 2009, 56, (6), pp. 21622173.
    2. 2)
      • 13. Yaoyuan, L., Chengbi, Z., Hong, M., et al: ‘Research on a new method to achieve low voltage ride through of PV’. 2014 Int. Conf. Power System Technology, Chengdu, 2014, pp. 10641070.
    3. 3)
      • 8. Takagi, T., Yamakosi, Y., Yamura, M., et al: ‘Development of new type fault locator using the one–terminal voltage and current data’, IEEE Trans. Power Appar. Syst., 1982, PAS–101, (8), pp. 28922898.
    4. 4)
      • 4. Sun, M., Wang, H., Zhu, X.: ‘Fault characteristics of photovoltaic power station and its influence on relay protection of transmission line’. 5th IET Int. Conf. Renewable Power Generation (RPG 2016), London, 2016, pp. 15.
    5. 5)
      • 16. Alepuz, S., Busquets-Monge, S., Bordonau, J., et al: ‘Control methods for low voltage ride-through compliance in grid-connected NPC converter based wind power systems using predictive control’. 2009 IEEE Energy Conversion Congress and Exposition, San Jose, CA, 2009, pp. 363369.
    6. 6)
      • 2. Idris, M.H., Ahmad, M.S., Abdullah, A.Z., et al: ‘Adaptive Mho type distance relaying scheme with fault resistance compensation’. 2013 IEEE 7th Int. Power Engineering and Optimization Conf. (PEOCO), Langkawi, 2013, pp. 213217.
    7. 7)
      • 18. Choi, M., Lee, S., Lee, D., et al: ‘A new fault location algorithm using direct circuit analysis for distribution systems’, IEEE Trans. Power Deliv., 2004, 19, (1), pp. 3541.
    8. 8)
      • 14. Li, K., Qian, J., Wu, H., et al: ‘Research on low voltage ride through of the grid-connected PV system’. Int. Conf. Advances in Energy, Environment and Chemical Engineering (AEECE 2015), Changsha, China, 2015.
    9. 9)
      • 3. Zhang, Z., Tao, Z., Ruirui, X., et al: ‘Protection for distribution network with photovoltaic integration’. 2016 IEEE PES Asia-Pacific Power and Energy Engineering Conf. (APPEEC), Xi'an, 2016, pp. 18221826.
    10. 10)
      • 6. Jia, K., Gu, C., Xuan, Z., et al: ‘Fault characteristics analysis and line protection design within a large-scale photovoltaic power plant’, IEEE Trans. Smart Grid, 2017, PP, (99), pp. 11.
    11. 11)
      • 17. Kase, T., Kurosawa, Y., Amo, H.: ‘Charging current compensation for distance protection’, IEEE Trans. Power Deliv., 2008, 23, (1), pp. 124131.
    12. 12)
      • 10. Chuang, C.L., Jiang, J.A., Wang, Y.C., et al: ‘An adaptive PMU-based fault location estimation system with a fault-tolerance and load-balancing communication network’. 2007 IEEE Lausanne Power Tech, Lausanne, 2007, pp. 11971202.
    13. 13)
      • 7. Pereira, D., Bretas, A.S.: ‘Extended ground distance relaying with fault resistance compensation’. 2010 Modern Electric Power Systems, Wroclaw, 2010, pp. 16.
    14. 14)
      • 12. Jia, K., Bi, T., Ren, Z., et al: ‘High frequency impedance based fault location in distribution system with DGs’, IEEE Trans. Smart Grid, 2016, PP, (99), pp. 11.
    15. 15)
      • 11. Jia, K., Thomas, D.W.P., Sumner, M.: ‘A new double-ended fault-location scheme for utilization in integrated power systems’, IEEE Trans. Power Deliv., 2013, 28, (2), pp. 594603.
    16. 16)
      • 1. Mohammedsaeed, E.K., Jia, K.: ‘Comparison of some low voltage ride-through strategies’. 43rd Annual Conf. IEEE Industrial Electronics Society, (IECON 2017), Beijing, China, 2017, pp. 152157.
    17. 17)
      • 5. Mortazavi, H., Mehrjerdi, H., Saad, M., et al: ‘Application of distance relay for distribution system monitoring’. 2015 IEEE Power & Energy Society General Meeting, Denver, CO, 2015, pp. 15.
    18. 18)
      • 9. Johns, A.T., Jamali, S.: ‘Accurate fault location technique for power transmission lines’, IEE Proc. C, Gener. Transm. Distrib., 1990, 137, (6), pp. 395402.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.8795