http://iet.metastore.ingenta.com
1887

access icon openaccess Study on lightning overvoltage and commutation failure in UHV AC/DC hybrid system

  • XML
    47.330078125Kb
  • HTML
    54.16015625Kb
  • PDF
    3.1433029174804688MB
Loading full text...

Full text loading...

/deliver/fulltext/10.1049/joe.2018.8791/JOE.2018.8791.html;jsessionid=1gfkrarvs3w2q.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.8791&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Ye, B., Yin, Y., Chen, S.: ‘Ultra-high voltage GIS system no-load long-line closing transient ultra-fast transient voltage’, Kunming Univ. Sci. Technol., 2013, 38, (1), pp. 5964.
    2. 2)
      • 2. Ji, R., Zhou, H., Yi, Q., et al: ‘Research on the characteristics of over-voltage during the closing of UHVAC system’, Electr. Power Syst. Prot. Control, 2011, 39, (14), pp. 8693.
    3. 3)
      • 3. Sun, Z., Liang, X., Sun, Y.: ‘Simulation of multi-infeed HVDC transmission system based on EMTDC’, Power Syst. Technol., 2006, 30, (S1), pp. 295298.
    4. 4)
      • 4. Wang, C., Liu, B.: ‘Multi-regional DC commutation failure on the sending end of the system’, Netw. Technol., 2013, 37, (4), pp. 10521057.
    5. 5)
      • 5. Shao, Y., Tang, Y., Guo, X., et al: ‘Flux failure analysis of multi-infeed HVDC system in North China and East China in 2015 UHV planning grid’, Power Syst. Technol., 2011, 35, (10), pp. 915.
    6. 6)
      • 6. Wang, X., Yang, Z., Guo, M., et al: ‘Study on the influence of UHVDC access on the stability of East China exchange system’, East China Electr. Power, 2009, 37, (1), pp. 8690.
    7. 7)
      • 7. Lin, L., Zhang, Y., Zhong, Q., et al: ‘Research on commutation failure in multi-infeed HVDC system’, Power Syst. Technol., 2006, 30, (17), pp. 4046.
    8. 8)
      • 8. Liu, J., Li, X., Wu, C., et al: ‘HVDC system commutation failure of the critical indicators’, Power Syst. Technol., 2009, 33, (8), pp. 812.
    9. 9)
      • 9. He, C., Li, X., Jin, X., et al: ‘HVDC transmission system commutation failure criterion to determine the standard’, Power Grid Technol., 2007, 31, (1), pp. 2024.
    10. 10)
      • 10. Ren, K., Li, X., Jin, X., et al: ‘Simulation of commutation failure caused by filter switching in inverter station in multi-infeed HVDC transmission system’, Power Syst. Technol., 2008, 32, (12), pp. 1722.
    11. 11)
      • 11. Huang, J., Zhao, C., Sun, Y.: ‘Influence of overvoltage on the transmission capacity of two different HVDC transmission systems’, East China Electr. Power, 2012, 40, (10), pp. 17671771.
    12. 12)
      • 12. Li, X.: ‘High voltage DC transmission system’ (Science Press, Beijing, 2010), pp. 122124.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.8791
Loading

Related content

content/journals/10.1049/joe.2018.8791
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address