http://iet.metastore.ingenta.com
1887

access icon openaccess Commutation failure caused by AC filter switching In HVDC system

  • PDF
    2.601742744445801MB
  • XML
    64.2919921875Kb
  • HTML
    75.291015625Kb
Loading full text...

Full text loading...

/deliver/fulltext/10.1049/joe.2018.8786/JOE.2018.8786.html;jsessionid=1eo8dd2ovld30.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.8786&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Li, X., Yi, J., Li, B., et al: ‘Simulation analysis and operation statistics of commutation failure in HVDC transmission system’, Power Syst. Technol., 2012, 36, (6), pp. 266271.
    2. 2)
      • 2. Wang, J.: ‘Research on transient process of RLC second order circuit under sinusoidal excitation’, J. Harbin Univ. Sci. Technol., 1999, 4, (1), pp. 9396.
    3. 3)
      • 3. Thio, C., Davies, J., Kent, K.: ‘Commutation failures in HVDC transmission systems’, IEEE Trans. Power Deliv., 1996, 11, (2), pp. 946957.
    4. 4)
      • 4. Ou, K., Ren, Z., Jing, Y.: ‘Research on commutation failure in HVDC transmission system’, Electr. Power Autom. Equip., 2003, 23, (5), pp. 58, 25.
    5. 5)
      • 5. Gong, J., Zhou, W., Gu, L.: ‘Analysis of switching commutation failure caused by converter station AC filter’, Power Energy, 2015, 36, (2), pp. 261264.
    6. 6)
      • 6. Yu, H., Chen, L., Liang, J.: ‘Investigation of commutation failure in Guangzhou converter station of Tian-Guang HVDC project’, High Volt. Appar., 2015, 51, (3), pp. 151156.
    7. 7)
      • 7. Ren, J., Li, X., Jin, X., et al: ‘Simulation study on commutation failure caused by switching AC filters of inverter stations in multi-infeed HVDC system’, Power Syst. Technol., 2008, 32, (12), pp. 1722.
    8. 8)
      • 8. Li, P., Xu, Z., Huang, Y., et al: ‘Algorithm for the parameters of AC filters in HVDC transmission system’, Proc. CSEE, 2008, 28, (16), pp. 115121.
    9. 9)
      • 9. Zhao, W., Liu, N., Lu, Y., et al: ‘Analysis of voltage disturbance influence on secondary circuits caused by AC filter switching in HVDC transmission system’, Autom. Electr. Power Syst., 2014, 38, (19), pp. 122126.
    10. 10)
      • 10. He, J.: ‘The emulation of the transient process of multi-arm single-tuning filter switching’, Railw. Trans., 1991, 5, (2), pp. 9299.
    11. 11)
      • 11. Wang, G., Li, Z., Huang, M., et al: ‘A control strategy for doubly-fed induction generator wind turbines under asymmetrical grid voltage conditions caused by faults’, Autom. Electr. Power Syst., 2010, 34, (4), pp. 4954, 102.
    12. 12)
      • 12. Wang, F., Liu, T., Zhou, S., et al: ‘Mechanism and quantitative analysis method for HVDC commutation failure resulting from harmonics’, Proc. CSEE, 2015, 35, (19), pp. 48884894.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.8786