access icon openaccess Influence of the typical vegetation ashes/particles on discharge characteristics of conductor-plane air gap

  • HTML
    45.77734375Kb
  • XML
    44.673828125Kb
  • PDF
    2.2241687774658203MB
Loading full text...

Full text loading...

/deliver/fulltext/10.1049/joe.2018.8500/JOE.2018.8500.html;jsessionid=t1pindf8ejko.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.8500&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Huang, D.C., Li, P., Ruan, J.J., et al: ‘Review on discharge mechanism and breakdown characteristics of transmission line gap under forest fire condition’, High Volt. Eng., 2016, 41, (2), pp. 622632.
    2. 2)
      • 2. Soulinaris, G.K., Halevidis, C.D., Polykrati, A.D., et al: ‘Evaluation of the thermal stresses and dielectric phenomena in the investigation of the causes of wildfires involving distribution power lines’, Electr. Power Syst. Res., 2014, 117, pp. 7683.
    3. 3)
      • 3. Wu, T., Ruan, J.J., Chen, C., et al: ‘Fire observation and experimental investigation on breakdown of air gap of AC transmission line under fires’. IEEE Conf. Power Eng. Autom., Wuhan, China, September 2011, pp. 339343.
    4. 4)
      • 4. Zhou, Z.Y., Ai, X., Lu, J.Z., et al: ‘A real-time analysis approach and its application for transmission line trip risk due to wildfire disaster’, Proc. CSEE, 2017, 37, (18), pp. 53215330.
    5. 5)
      • 5. Wu, T., Hu, Y., Ruan, J.J., et al: ‘Air gap breakdown mechanism of model AC transmission line under forest fires’, High Volt. Eng., 2011, 37, (5), pp. 11141122.
    6. 6)
      • 6. Deng, H.M.: ‘The research on characteristics of two-phase mixture discharges under lightning impulse voltage’, PhD thesis, Huazhong University of Science and Technology, 2010.
    7. 7)
      • 7. Hara, M., Negara, Y., Setoguchi, M., et al: ‘Particle-triggered pre-breakdown phenomena in atmospheric air gap under AC voltage’, IEEE Trans. Dielectr. Electr. Insul., 2005, 12, (5), pp. 10711081.
    8. 8)
      • 8. Sukhnandan, A., Hoch, D.A.: ‘Fire induced flashovers of transmission lines: theoretical models’. 6th Africon. Conf. Africa, George, South Africa, October 2002, pp. 617622.
    9. 9)
      • 9. Fonseca, J.R., Tan, A.L., Silva, R.P., et al: ‘Effects of agricultural fires on the performance of overhead transmission lines’, IEEE Trans. Power Deliv., 1990, 5, (2), pp. 687694.
    10. 10)
      • 10. Robledo, M.A., Guzman, E., Hernandez, J.L.: ‘Dielectric characteristics of a model transmission line in the presence of fies’, IEEE Trans. Electr. Insul., 1991, 26, (4), pp. 776782.
    11. 11)
      • 11. Khan, Y., Sakai, K.I., Lee, E.K., et al: ‘Motion behavior and deactivation method of free-conducting particle around spacer between diverging conducting plates under dc voltage in atmospheric air’, IEEE Trans. Dielectr. Electr. Insul., 2003, 10, (3), pp. 444457.
    12. 12)
      • 12. Sadurski, K.J., Reynders, J.P.: ‘High voltage AC breakdown in presence of fires’. Int. Symp. High Voltage Eng., New Orleans, L.A., USA, August 1989, pp. 14.
    13. 13)
      • 13. Naido, P., Swift, D.A.: ‘Large particle initiated breakdown of an atmospheric air gap: relating to AC power line faults caused by sugar cane fires’. Int. Symp. High Voltage Eng., Yokohama, Japan, August 1993, pp. 8184.
    14. 14)
      • 14. Negara, Y., Yaji, K., Suehiro, J., et al: ‘DC corona discharge from floating particle in low pressure SF6’, IEEE Trans. Dielectr. Electr. Insul., 2006, 13, (6), pp. 12081216.
    15. 15)
      • 15. Yang, X.H., Lu, G.J., Liu, S.L.: ‘Study on the relationship between exposed area and the heat release rate of wood crib’, Fire Theory Study, 2010, 29, (1), pp. 1315.