http://iet.metastore.ingenta.com
1887

access icon openaccess Calibration of a sensor for an ion electric field under HVDC transmission lines

Loading full text...

Full text loading...

/deliver/fulltext/joe/2019/16/JOE.2018.8400.html;jsessionid=vlwt7wkgg9uq.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fjoe.2018.8400&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Bresesti, P., Kling W, L., Hendriks, R. L., et al: ‘HVDC connection of offshore wind farms to the transmission system’, IEEE Trans. Energy Convers., 2007, 22, (1), pp. 3743.
    2. 2)
      • 2. Tihanyi, L.: ‘Electromagnetic compatibility in power electronics’, Electromagn. Compat. Power Electron., 1995, 1, (1), pp. 56123.
    3. 3)
      • 3. Liu, J., Zou, J., Tian, J., et al: ‘Analysis of electric field, ion flow field, and corona loss of same-tower double-circuit HVDC lines using improved FEM’, IEEE Trans. Power Deliv., 2008, 24, (1), pp. 482483.
    4. 4)
      • 4. Yin, H., Zhang, B., He, J., et al: ‘Time-domain finite volume method for ion-flow field analysis of bipolar high-voltage direct current transmission lines’, IET. Gener. Transm. Distrib., 2012, 6, (8), pp. 785791.
    5. 5)
      • 5. Xiao, F., Zhang, B., Mo, J., et al: ‘Calculation of 3-D ion flow field at the crossing of HVDC transmission lines by method of characteristics’, IEEE Trans. Power Deliv., 2017, 1, (1), pp. 99105.
    6. 6)
      • 6. Maruvada, P. S., Dallaire, R. D., Pedneault, R.: ‘Development of field-mill instruments for ground-level and above-ground electric field measurement under HVDC transmission lines’, IEEE Trans. Power Appar. Syst., 1983, 102, (3), pp. 738744.
    7. 7)
      • 7. Kasaba, Y., Hayakawa, H., Ishisaka, K., et al: ‘DC electric field measurement by the double probe system aboard Geotail and its simulation’. AGU Fall Meeting.AGU Fall Meeting Abstracts, San Francisco, USA, 2005.
    8. 8)
      • 8. Riehl, P. S., Scott, K.L., Muller, R.S., et al: ‘Electrostatic charge and field sensors based on micromechanical resonators’, J. Micromech. Syst., 2003, 12, (5), pp. 577589.
    9. 9)
      • 9. Ma, Q., Huang, K., Yu, Z., et al: ‘A MEMS-based electric field sensor for measurement of high-voltage DC synthetic fields in air’, IEEE Sens. J., 2017, 1, (1), pp. 78667876.
    10. 10)
      • 10. Wijeweera, G., Bahreyni, B., Shafai, C., et al: ‘Micromachined electric-field sensor to measure AC and DC fields in power systems’, IEEE Trans. Power Deliv., 2009, 24, (3), pp. 988995.
    11. 11)
      • 11. Li, B., Peng, C., Zheng, F., et al: ‘A decoupling calibration method based on genetic algorithm for three dimensional electric field sensor’, IEEE Sens. J., 2017, 1–3, pp. 13.
    12. 12)
      • 12. Withers, R., Melcher, J., Richmann, J.: ‘Charging, migration and electro hydrodynamic transport of aerosols’, J. Electrost., 1978, 5, (SEP), pp. 225239.
    13. 13)
      • 13. Misakian, M.: ‘Generation and measurement of dc electric fields with space charge’, J. Appl. Phys., 1998, 52, (5), pp. 31353144.
    14. 14)
      • 14. Zhang, B., He, J., Ji, Y.: ‘Dependence of the average mobility of ions in air with pressure and humidity’, IEEE Trans. Dielectr. Electr. Insul., 2017, 24, (2), pp. 923929.
    15. 15)
      • 15. Qin, B., Jiang, G.: ‘The generation and measurement of DC Ion flow fields’, High Volt. Eng., 1986, 1, (1), pp. 6165.
http://iet.metastore.ingenta.com/content/journals/10.1049/joe.2018.8400
Loading

Related content

content/journals/10.1049/joe.2018.8400
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address