The influence of resistance switching on the design of high-voltage air-blast circuit-breakers

Access Full Text

The influence of resistance switching on the design of high-voltage air-blast circuit-breakers

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Journal of the Institution of Electrical Engineers - Part II: Power Engineering — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

This paper reviews various problems which are met in designing highvoltage air-blast circuit-breakers, and the way in which the application resistance switching confers another degree of freedom upon the designer in meeting the many conflicting requirements.It is first of all shown that a circuit-breaker must not only break its rated breaking current but must also limit the value of surge voltage which it causes while it is opening the circuit. This can be brought about by limiting the electric strength of the breaker contact gaps.An experimental method of determining the electric strength of the nozzles under air-flow conditions is then explained, followed by discussion of the means by which resistance switching enables the designer to control the breaking capacity and the electric strength of the nozzles independently.A 132-kV breaker designed in conformity with the conclusions reached is described, and the results of a full-scale test set-up are given.The paper then gives an analysis of the validity of “unit testing” applied to multi-break breakers with resistance switching, as compared with the present two-part testing applied to oil circuit-breakers in accordance with B.S. 116, Part 2.In conclusion, proposals are made for a series of type-test duties to be applied to air-blast circuit-breakers, in order to prove compliance with their breaking-capacity ratings.

Inspec keywords: circuit breakers

Subjects: Switchgear

http://iet.metastore.ingenta.com/content/journals/10.1049/ji-2.1944.0084
Loading

Related content

content/journals/10.1049/ji-2.1944.0084
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Comment
A comment has been published for this article:
Discussion on “The influence of resistance switching on the design of high-voltage air-blast circuit-breakers” before the Western Centre, at Cardiff, 15th May, 1944
Correspondence
This article has following corresponding article(s):
The influence of resistance switching on the design of high-voltage air-blast circuit-breakers
Comment
A comment has been published for this article:
Discussion on “The influence of resistance switching on the design of high-voltage air-blast circuit-breakers” before the North-Western Centre, at Manchester, 16th January, 1945
Comment
A comment has been published for this article:
Discussion on “The influence of resistance switching on the design of high-voltage air-blast circuit-breakers” before the North-Eastern Centre, at Newcastle, 8th January, 1945