http://iet.metastore.ingenta.com
1887

Fundamental electrical characteristics of synchronous turbo-generators

Fundamental electrical characteristics of synchronous turbo-generators

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
Journal of the Institution of Electrical Engineers - Part II: Power Engineering — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The paper deals mainly with the MVA rating or the power factor rating, and with the synchronous-reactance value of large, non-salientpole synchronous generators. Essential factors for selecting these values are discussed and a method of making that selection is proposed. An analysis is made of the manner in which the two values affect the operation of the generator. From a power chart based on the classical circle diagram, diagrams of “working area” limitations are derived and represented in co-ordinates of reactive power versus active power, power factor versus active power and excitation current versus active power. These diagrams are suitable both for comparing properties of different generators when ordering new units, and for supervision of operation of generators. Problems of capacitive loads and of synchronous stability of generators are discussed. From a comparison of external characteristics of an isolated generator, with different load characteristics, conceptions of voltage stability and of “absolute power limit” in respect of that voltage stability are derived. The influence is discussed of stator-winding resistance and of saturation on representative diagrams and curves. The paper is illustrated by an example of an actual 50-MW, 58-MVA turbo-generator.

References

    1. 1)
      • M.G. Say , E.N. Pink . (1936) , The Performance and Design of Alternating-Current Machines.
    2. 2)
      • R. Richter . Alternating-Current Machines, Synchronous Machines.
    3. 3)
      • J. Fallou . , Systems for Energy Transmission.
    4. 4)
      • O.G.C. Dahl . (1928) , Electric Circuits.
    5. 5)
      • W.D. Horsley . The Stability Characteristics of Alternators and of Large Interconnected Systems. Journal I.E.E.
    6. 6)
      • C.F. Dalziel . Static Power Limits of Synchronous Machines. Trans. American I.E.E.
    7. 7)
      • O.E. Shirley . Stability Characteristics of Alternators. Trans. American I.E.E.
    8. 8)
      • T.F. Wall . The Circle Diagram. Electrician
    9. 9)
      • L.A. March , S.B. Crary . Armature Leakage Reactance of Synchronous Machines. Trans. American I.E.E.
    10. 10)
      • C. Kingsley . Saturated Synchronous Reactance. Trans. American I.E.E.
http://iet.metastore.ingenta.com/content/journals/10.1049/ji-2.1944.0022
Loading

Related content

content/journals/10.1049/ji-2.1944.0022
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
Correspondence
This article has following corresponding article(s):
Fundamental electrical characteristics of synchronous turbo-generators
This is a required field