Compensated-current differential relay for protection of transformers

Access Full Text

Compensated-current differential relay for protection of transformers

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IEE Proceedings - Generation, Transmission and Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large excitation current, which can cause malfunction of a differential relay. The paper describes a solution, its implementation within a compensated-current differential relay and its evaluation using an EMTP-based simulator and a relay test set. The relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. Before the core enters saturation, the relay calculates the core-loss current and uses it to modify the measured differential current. If the core then enters saturation, the initial value of the core flux is obtained by inserting the modified differential current at the start of saturation into the magnetisation curve. The actual core flux seen during a fault or a nonfault event, such as magnetic inrush or over-excitation, is then derived and used in conjunction with the magnetisation curve to calculate the magnetising current. A modified differential current is then derived that compensates for the core-loss and magnetising currents. The operating performance of the compensated current differential relay was compared against a conventional differential relay. Results indicate that the compensated relay remained stable during severe magnetic inrush and over-excitation, because the exciting current was successfully compensated. The paper concludes by implementing the relay on a hardware platform based on a digital signal processor. The relay correctly discriminates magnetic inrush and over-excitation from an internal fault and is not affected by the level of remanent flux.

Inspec keywords: magnetic flux; power transformer testing; EMTP; fault currents; power transformer protection; transformer cores; digital signal processing chips; relay protection; remanence

Other keywords: digital signal processor; fault event; hardware platform; magnetic inrush; overexcitation current; EMTP-based simulator; core saturation; nonfault event; transformer protection; core-loss current; core flux; magnetisation curve; remanent flux; magnetising current; compensated-current differential relay; relay test set

Subjects: Power engineering computing; Transformers and reactors; Microprocessors and microcomputers; Digital signal processing chips; Magnetic cores

References

    1. 1)
      • C.H. Einvall , J.R. Linders . A three-phase differential relay for transformer protection. IEEE Trans. Power Appar. Syst. , 6 , 1971 - 1980
    2. 2)
      • Kang, Y.C., Lee, B.E., Kang, S.H., Kim, S.S., Lee, J.K.: `A transformer protective relaying algorithm using the ratio of induced voltages', Presented at IEEE Power Engineering Society Summer Meeting (PES), 2001, July 2001, Vancouver, Canada.
    3. 3)
      • A.G. Phadke , J.S. Thorp . (2009) Computer relaying for power systems.
    4. 4)
      • C.D. Hayward . Harmonic-current-restrained relays for transformer differential protection. Trans. Amer Inst. Electr. Eng. , 377 - 382
    5. 5)
      • Heydeman, J., Sluis, L.: `Flux-based current-differential relay for power transformer protection', IEE 5th Int. Conf. on Dev. Power Syst. Protection, March 1993, York, UK, p. 77–80.
    6. 6)
    7. 7)
      • R.L. Sharp , W.E. Glassburn . A transformer differential relay with second-harmonic restraint. Trans. Amer Inst. Electr. Eng. Trans. Part III , 913 - 918
    8. 8)
      • A.G. Phadke , J.S. Thorp . A new computer-based flux-restrained current-differential relay for power transformer protection. IEEE Trans. Power Appar. Syst. , 11 , 3624 - 3629
    9. 9)
      • C.W. Mathews . An improved transformer differential relay. Trans. Amer Inst. Electr. Eng. Part III , 645 - 650
    10. 10)
      • (1986) Electromagnetic transients program theory book.
    11. 11)
    12. 12)
http://iet.metastore.ingenta.com/content/journals/10.1049/ip-gtd_20040476
Loading

Related content

content/journals/10.1049/ip-gtd_20040476
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading