Load-imposed instability and performance degradation in a regulated converter

Load-imposed instability and performance degradation in a regulated converter

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IEE Proceedings - Electric Power Applications — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The stability and performance of a regulated converter is analysed based on its closed-loop output impedance. System theory is used to obtain a set of transfer functions that define the internal stability of an interconnected system consisting of source and load converters. The internal stability is described in terms of the ratio of the output impedance of the source converter and the input impedance of the load converter known as the minor-loop gain. Thus, the closed-loop output impedance of a source converter can be used to define safe operating areas that avoid instabilities in the load impedance. It is shown that the margins associated with the minor-loop gain (i.e. the gain and phase margins) do not generally match the margins of the output-voltage loop gain. The relationship is especially weak at frequencies close to and beyond the crossover frequency of the loop gain. This means that the margins given to the minor-loop gain should be gradually increased as the voltage-loop-gain crossover frequency is approached so as to avoid performance degradation (i.e. changes in margins and crossover frequency) in the supply converter. Experimental evidence is provided based on a buck converter under voltage- and peak-current-mode control.