Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Novel line-interactive uninterruptible power supply

Novel line-interactive uninterruptible power supply

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IEE Proceedings - Electric Power Applications — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

In the paper, a novel uninterruptible power supply (UPS) is proposed with the performance of input current harmonic suppression, input power factor correction and output voltage regulation. This UPS comprises two power converters, a shunt power converter and a series power converter. The shunt power converter is connected to the utility via a link inductor, for providing a compensating voltage, to suppress the input current harmonic and improve the input power factor. The series power converter is connected serially to the load to provide a clean and regulated output voltage. A voltage-mode control algorithm with fast response and simple control circuit is proposed to control the shunt power converter. The series power converter is controlled by a current-mode control to ensure the quality of output voltage. A single-phase prototype is developed and tested to verify the performance of the proposed UPS. Experimental results show that the proposed UPS has expected performance.

References

    1. 1)
    2. 2)
    3. 3)
      • Silva, S.A.O., Donoso-Garicia, P., Cortizo, P.C., Seixas, P.F.: `A comparative analysis of control algorithms for three-phase line-interactive UPS systems with series-parallel active power-line conditioning using SRF method', IEEE Power Electronics Specialists Conference, 2000, Ireland, p. 1023–1028.
    4. 4)
      • Lin, Y., Joos, G., Lindsay, J.F.: `Performance analysis of parallel-processing UPS systems', Applied Power Electronics Conference and Exposition, 1993, USA, p. 533–539.
    5. 5)
      • Su, G.J.: `Design and analysis of a low cost, high performance single phase UPS system', IEEE Power Electronics Specialists Conference, 2001, Canada, p. 900–906.
    6. 6)
      • Qin, Y., Du, S.: `Line interactive UPS with the DSP based active power filter', Telecommunications Energy Conference, 1995, The Netherlands, p. 421–425.
    7. 7)
      • S. Karve . Three of a kind [UPS Topologies, IEC Standard]. IEE Rev. , 27 - 31
    8. 8)
      • Rathmann, S., Warner, H.A.: `New generation UPS technology, the delta conversion principle', IEEE Industry Applications Conference, 1996, USA, 4, p. 2389–2395.
    9. 9)
      • C.M. Liaw , T.H. Chen , T.C. Wang , G.J. Cho , C.M. Lee , C.T. Wang . Design and implementation of a single phase current-forced switching mode bilateral converter. IEE Proc., Electr. Power Appl. , 129 - 136
    10. 10)
      • Rodriguez, E., Vazquez, N., Hernandez, C., Visairo, H., Arau, J.: `A novel AC-UPS with PFC and fast dynamic response', IEEE Power Electronics Specialists Conference, 2001, Canada, p. 893–899.
    11. 11)
      • Wu, J.C., Jou, H.L., Wu, K.D., Sun and, C.B., Chen, J.Y.: `A fast voltage-controlled active power filter without current sensor', 21stSymposium on Electrical Power Engineering of Taiwan, 2000, Taiwan, Republic of China, p. 811–815.
    12. 12)
http://iet.metastore.ingenta.com/content/journals/10.1049/ip-epa_20040481
Loading

Related content

content/journals/10.1049/ip-epa_20040481
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address