Improved DSP-controlled online UPS system with high real output power

Improved DSP-controlled online UPS system with high real output power

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IEE Proceedings - Electric Power Applications — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

A circuit topology is proposed for single-phase online UPS systems. The proposed circuit incorporates a built-in bidirectional AC/DC converter, which provides power factor correction and active power filtering. The input stage, based on a bidirectional AC/DC converter, functions as a rectifier with unity power factor correction for normal AC line mode operation, and as an active power filter for outage mode operation. During input power failure, the bidirectional AC/DC converter functions as an active power filter, providing reactive power to the load. Simultaneously, the DC/AC voltage inverter output stage supplies real power from the battery bank to the critical load. The real power capability is improved compared with that of a conventional online UPS system, and extra loads can be connected to the UPS system during outage. The power circuit of the proposed UPS system is presented and analysed. Circuit models are derived and a UPS digital control system using a digital signal processor (DSP) is developed. Finally, simulated and experimental results obtained from a laboratory prototype are presented to confirm the feasibility and features of the proposed UPS scheme.

References

    1. 1)
      • Krishnan, R.: `Design and development of a high frequency on-line uninterruptible power supply', Proc. IEEE Industrial electronics, control, and instrumentation Conf. (IECON), 1995, p. 578–583.
    2. 2)
      • De Souza, F.P., Barbi, I.: `Power factor correction of linear and nonlinear loads employing a single phase active power filter based on a full-bridge current source inverter controlled through the sensor of the AC mains current', Proc. IEEE Power electronics specialist Conf. (PESC), 1999, p. 387–392.
    3. 3)
      • N. Abdel-Rahim , J.E. Quaicoe . Analysis and design of a multiple feedback loop control strategy for a single-phase voltage-source UPS inverter. IEEE Trans. Power Electron. , 4 , 532 - 541
    4. 4)
    5. 5)
      • Liang, T.J., Shyu, J.L., Chen, J.F.: `High real output power on-line UPS system with built-in reactive power compensation', Proc. IEEE Power electronics specialist conf. (PESC), 2001, p. 1555–1560.
    6. 6)
      • Hirachi, K., Sakane, M., Matsui, T., Kajima, A., Nakaoka, M.: `Cost-effective practical developments of a high performance and multi-functional UPS with new system configurations and their specific control implementations', Proc. IEEE Power electronics specialist conf (PESC), 1995, p. 480–485.
    7. 7)
    8. 8)
    9. 9)
      • Joos, G., Lin, Y., Ziogas, P.D., Lindsay, J.F.: `An on-line UPS with improved input-output characteristics', Proc. IEEE Applied power electronics Conf. (APEC), 1992, p. 598–605.
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
http://iet.metastore.ingenta.com/content/journals/10.1049/ip-epa_20040020
Loading

Related content

content/journals/10.1049/ip-epa_20040020
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address