Enhancement and laboratory implementation of neural network detection of short circuit faults in DC transit system

Access Full Text

Enhancement and laboratory implementation of neural network detection of short circuit faults in DC transit system

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IEE Proceedings - Electric Power Applications — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The continuing development of neural networks for real-time detection of DC short circuit faults in DC transit systems is described. The Discrete Wavelet Transform has been previously applied to detect any surges in DC third rail current waveform. In the event of a surge, the wavelet transform extracts a feature vector from the current waveform and feeds it to a self-organising neural network. The neural network then determines whether the feature vector belongs to a fault current surge due to short circuit occurring across the DC-link capacitor within a chopper train, or to a normal surge due to the starting of the chopper train. Perfect classification has been achieved between different cases of train starting and short circuits. The robustness of the neural network is further proven using extended data sets for training and testing and laboratory implementation. A new simulation model for the inverter trains is developed. A new type of short circuit fault occurring between third rail and track is modelled. For testing the fault detection scheme within the laboratory environment, a hardware model of the DC transit system is carefully built using an induction motor, laboratory power supplies and electronic models of railway components. Two neural networks are trained using the simulation data, and tested using the simulation and laboratory-measured data. Perfect classification is again achieved from both neural networks. The laboratory environment provides a valuable platform for fine-tuning the neural networks and for in-depth studies into the effects of practical constraints such as measurement noises and nonlinearities of the hardware models.

Inspec keywords: rapid transit systems; power capacitors; fault diagnosis; neural nets; short-circuit currents; traction power supplies; power system analysis computing; power distribution faults

Other keywords: DC transit system; discrete wavelet transform; current waveform; inverter trains; self-organising neural network; feature vector; DC-link capacitor; robustness; power supplies; chopper train; measurement noises; induction motor; neural network detection; short circuit faults; simulation model

Subjects: Power engineering computing; Other power apparatus and electric machines; Transportation; Neural computing techniques; Distribution networks

References

    1. 1)
      • Michel Misiti , Yves Misiti , Georges Oppenheim , Jean-Michel Poggi . (1996) Wavelet Toolbox For Use With MATLAB.
    2. 2)
      • A. Rhor . Line fault detection for direct current railways. Brown Boveri Rev. , 678 - 681
    3. 3)
      • Digby, G., Brown, J.D.: `The development of a neural network-based multi-function protection relay', Proceedings of Computers in Railways V-2, Comprail 96, p. 157–166.
    4. 4)
      • S. Haykin . (1998) Neural network – a comprehensive foundation.
    5. 5)
      • `IEEE recommended practice for protection and coordination of industrial and commercial power systems', IEEE STD 242-2001, 2001.
    6. 6)
      • Fracchia, M., Hill, R.J., Pozzobon, P., Sciutto, G.: `Accurate track modelling for fault current studies on third-rail metro railways', Proceedings of the ASME/IEEE: Joint (Railroad and Area 1994 Annual Technical Conference), 1994, p. 97–102.
    7. 7)
      • T. Wildi , M.J. De Vito . Investigations in Electric Power Technology.
    8. 8)
      • L.F. Shampine , M.W. Reichelt . (1996) The MATLAB ODE Suite.
    9. 9)
      • S. Chang , T. Feng , A. Khambadkone , S. Kumar . Remote short-circuit current determination in DC railway systems using wavelet transform. IEE Proc., Electr. Power Appl. , 6 , 1 - 2
    10. 10)
      • J.C. Goswami , A.K. Chan . (1999) Fundamentals of Wavelets: Theory, Algorithms and Applications.
    11. 11)
      • Xu, Zhao: `Modelling, Simulation and Short Circuit Detection in DC Transit System', 2002, MEng, National University of Singapore, Department of Electrical and Computer Engineering, submitted to.
    12. 12)
      • L. Jingcheng , J.L. Kohler . DC trolley fires – a new solution to an old problem. IEEE Trans. Ind. Appl. , 4 , 726 - 732
    13. 13)
      • Chang, C.S., Khambadkone, A., Xu, Zhao: `Modelling and Simulation of DC Transit System with VSI-fed Induction Motor Driven Train Using PSB/MATLAB', Proceedings of 4th IEEE International Conference on Power electronics and drive systems, 2001.
    14. 14)
      • Hydro-Québec, TEQSIM International, and The Math Works, Inc., `Power System Blockset User's Guide', copyright 1984–1999.
    15. 15)
      • J.A. Fernandez . A new concept for protecting lines against faults in DC traction networks. Brown Boveri Rev. , 372 - 378
    16. 16)
http://iet.metastore.ingenta.com/content/journals/10.1049/ip-epa_20030308
Loading

Related content

content/journals/10.1049/ip-epa_20030308
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading