© The Institution of Electrical Engineers
An accelerometer based on an automatic force-balance principle has been developed with a view to measuring linear acceleration from 0.01 to 1.0 g, with overall accuracy of 0.1% under static as well as dynamic conditions in the frequency range from 0 to 70 Hz. The analysis of errors of components of various blocks and its experimental verification, the exact determination of damping ratio, and the phenomenon of reduction of undamped natural frequency arising out of the so called ‘piston effect’, caused by the highly viscous damping fluid, are some of the highlights in the determination of the performance. Finally, it is concluded that this linear accelerometer, using a new technique of calibration and an accurate measuring device, can be considered as a standard accelerometer.
References
-
-
1)
-
Clark, N.H.: `How accurate is your accelerometer', Natl. Conf. Publ. Inst. Eng. Aust. N76 – 79, 11–12 October 1976, Sydney, Australia, p. 105–106, Vibration and noise control engineering.
-
2)
-
H. Canton
.
Survey of the various methods of calibrating acceleration transducers used at the Centre d'Etudes Scientifiques et Techniques d'Aquitaine.
J. Soc. Environ. Eng.
,
2 ,
27 -
29
-
3)
-
M. Takizawa ,
T. Suzuki ,
M. Otsuki
.
Performances and characteristics of floated pendulum accelerometer with a passive magnetic suspension.
Bull. Jpn. Soc. Precis. Eng.
,
2 ,
82 -
88
-
4)
-
B.E. Jones
.
Feedback in instruments and its applications.
J. Phys. E
,
145 -
158
-
5)
-
Delattre, M.: `The ONERA low-', Proceedings of 5th international instrumentation symposium, 25th–28th March 1968, Cranfield, England, p. 12–17.
-
6)
-
B.E. Jones
.
(1977)
, Instrumentation, measurement and feedback.
-
7)
-
I.G. Scott
.
(1954)
, The behaviour of oil damping in a variable inductance acceleration transducer.
-
8)
-
W.K. Clark ,
W. Lederman ,
M.F. Smith
.
The fluidic vibrating string accelerometer.
Automatica
,
4 ,
497 -
503
-
9)
-
C.S. Draper ,
W. McKay ,
S. Lees
.
(1953)
, Instrument engineering.
-
10)
-
R.C. Mehta
.
The development of accelerometers.
Electron. & Power
,
304 -
307
-
11)
-
H.K.P. Neubert
.
(1975)
, Instrument transducers.
-
12)
-
C.H. Dix ,
A.E. Bailey
.
Electrical standards of measurement, Part I, D.C. and low-frequency standards.
Proc. IEE
-
13)
-
R.C. Mehta
.
Determining peak alternating voltage at very low frequencies.
Instruments & Control Syst.
,
79 -
81
-
14)
-
G.F. Serra
.
Force balance principle raises accuracy of digital pressure transducers.
J. Instrum. Soc. Am.
,
8 ,
51 -
54
-
15)
-
W.R. MacDonald
.
(1957)
, Design of feedback transducers.
-
16)
-
B.E. Jones ,
N.A. Mirza
.
Feedback electrostatic wattmeter using a noncontact moving-coil actuator.
Proc. IEE
,
12 ,
1259 -
1262
-
17)
-
L.M. Roylance ,
J.B. Angell
.
A batch-fabricated silicon accelerometer.
IEEE Trans.
,
12 ,
1911 -
1917
-
18)
-
A.W. Orlacchio
.
Shock and vibration transducers.
Electron. Des.
,
11 ,
68 -
75
-
19)
-
Thomas, I.L., Evans, R.H.: `Performance characteristics and methods of testing of force feedback accelerometers', 67183, Technical report, August 1967, p. 32–33.
-
20)
-
J.C. Gille ,
M.J. Pelegrin ,
P. Decauline
.
(1959)
, Feedback control system-analysis, synthesis and design book.
-
21)
-
E.J. Clabburn
.
An inexpensive fast response displacement transducer.
J. Phys. E
,
248 -
250
-
22)
-
J.H. van Nierop
.
A low-cost linear accelerometer.
J. Phys. E
,
880 -
882
http://iet.metastore.ingenta.com/content/journals/10.1049/ip-a-1.1987.0007
Related content
content/journals/10.1049/ip-a-1.1987.0007
pub_keyword,iet_inspecKeyword,pub_concept
6
6