Considering that intravenous in blood infusion, usually applied without a proper control of the progress and velocity under unreliable manual monitoring practice, is the most popular and frequent clinical activity throughout the world, which can potentially endanger a patient's life, leads to a huge burden as patients, relatives and nursing staff can cause serious cases of medical negligence. In order to resolve this problem and provide a networkable solution the authors propose a novel radio frequency identification-based wireless sensor networkable intravenous infusion monitoring system. The proposed system is a wireless sensor system based on taking a fork-type light barrier as a sensor, a micro-control unit (MCU) as a ZigBee-based radio frequency device. The system's performance is evaluated through some laboratory experiments using tuning algorithm to demonstrate that the results show the required accuracy of the system to meet practical needs.
References
-
-
1)
-
A.S. Chipcon
.
CC2420 2.4 GHz IEEE 802.15.4/ZigBee-ready RF Transceiver.
-
2)
-
A. Wheeler
.
Commercial applications of wireless sensor networks using ZigBee.
IEEE Commun. Mag.
,
4 ,
70 -
77
-
3)
-
http://www.zigbee.org, accessed December 2009.
-
4)
-
N. Simon
.
Impact of infusion method on amikacin serum levels in humans.
Pulmonary Pharmacol. Therapeut.
,
4 ,
324 -
326
-
5)
-
S. Robert ,
S.J. Wilcox
.
The link between intravenous multiple pump flow errors and infusion system mechanical compliance Murphy.
Anesth. Analg.
,
5 ,
1297 -
1302
-
6)
-
H. Guo ,
A. Liang ,
L. Li ,
X. Guan ,
H. Bian
.
Test study on fluid height of Murphy's dropper and loss of transfusing whole blood erythrocyte.
J. Pract. Nurs.
,
5
-
7)
-
Ni, S.-Y., Tseng, Y.-C., Chen, Y.-S., Sheu, J.-P.: `The broadcast storm problem in a mobile ad hoc network', Proc. Int. ACM/IEEE Int. Conf. on Mobile Computing and Networking, August 1999, Seattle, Washington, USA, p. 151–162.
-
8)
-
M. de Berg ,
M. van Kreveld ,
M. Overmars ,
O. Schwarzkopf
.
(1997)
Computational geometry: algorithms and applications.
-
9)
-
http://focus.ti.com.cn/cn/lit/ug/swru070k/swru070k.pdf, accessed December 2009.
-
10)
-
S. Goldstein
.
(1965)
Modern developments in fluid dynamics: an account of theory and experiment relating to boundary layers, turbulent motion and wakes.
-
11)
-
M. Ziser ,
M. Feezor ,
M.W. Skolaut
.
Regulating intravenous fluid flow: controller versus clamps.
Am. J. Hosp. Pharm.
,
8 ,
1090 -
1094
-
12)
-
G.K. Batchelor
.
The effect of homogeneous turbulence on material lines and surfaces.
Proc. R. Soc. Lond.
,
349 -
366
-
13)
-
R. Dudde ,
T. Vering ,
G. Piechotta ,
R. Hintsche
.
Computer-aided continuous drug infusion: setup and test of a mobile closed-loop system for the continuous automated infusion of insulin.
IEEE Trans. Inf. Technol. Biomed.
,
2 ,
395 -
402
-
14)
-
M. Weiss ,
M.I. Hug ,
T. Neff ,
J. Fischer
.
Syringe size and flow rate affect delivery from syringe pumps.
Can. J. Anaesth.
,
10 ,
1031 -
1035
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-wss.2011.0031
Related content
content/journals/10.1049/iet-wss.2011.0031
pub_keyword,iet_inspecKeyword,pub_concept
6
6