Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Classification of low level surface electromyogram using independent component analysis

Classification of low level surface electromyogram using independent component analysis

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Signal Processing — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

There is an urgent need for a simple yet robust system to identify natural hand actions and gestures for controlling prostheses and other computer-assisted devices. Surface electromyogram (SEMG) is a non-invasive measure of the muscle activities but is not reliable because there are a multiple simultaneously active muscles. This study proposes the use of independent component analysis (ICA) for SEMG to separate activity from different muscles. A mitigation strategy to overcome shortcomings related to order and magnitude ambiguity related to ICA has been developed. This is achieved by using a combination of unmixing matrix obtained from FastICA analysis and weight matrix derived from training of the supervised neural network corresponding to the specific user. This is referred to as ICANN (independent component analysis neural network combination). Experiments were conducted and the results demonstrate a marked improvement in the accuracy. The other advantages of this system are that it is suitable for real time operations and it is easy to train by a lay user.

References

    1. 1)
      • Y. Koike , M. Kawato . Human interface using surface electromyography signals. Electron. Commun. , 15 - 22
    2. 2)
      • A. Cichocki , S. Amari . (2002) Adaptive blind signal and image processing: learning algorithms and applications.
    3. 3)
      • Rekimoto, J.: `Gesture wrist and gesture pad: unobtrusive wearable interaction devices', Proc. Fifth IEEE Int. Symp. Wearable Computers, 2001.
    4. 4)
      • Ju, P., Kaelbling, L., Singer, Y.: `State-based classification of finger gestures from electromyographic signals', Proc. 17th Int. Conf. Machine Learning, 2000, p. 439–446.
    5. 5)
      • Zhao, J., Xie, Z., Jiang, L., Cai, H., Liu, H., Hirzinger, G.: `EMG control for a five-fingered underactuated prosthetic hand based on wavelet transform and sample entropy', Proc. Int. Conf. Intelligent Robots and Systems, 2006, p. 3215–3220.
    6. 6)
      • D. Graupe , W. Cline . Functional separation of EMG signals via ARMA identification methods for prosthesis control purposes. IEEE Trans. Syst. Man Cybern. , 252 - 259
    7. 7)
      • Headon, R., Coulouris, G.: `Supporting gestural input for users on the move', Proc. IEE Eurowearable, 2003, p. 107–112.
    8. 8)
      • C.D. Meyer . (2000) Matrix analysis and applied linear algebra.
    9. 9)
    10. 10)
      • A. Hyv̈arinen , J. Harhunen , E. Oja . (2001) Independent component analysis.
    11. 11)
      • P.C. Doerschuk , D.E. Gustafson , A.S. Willsky . Upper extremity limb function discrimination using EMG signal analysis. IEEE Trans. Biomed. Eng. , 1 , 18 - 28
    12. 12)
      • Nishikawa, D., Yu, W., Yokoi, H., Kakazu, Y.: `Emg prosthetic hand controller discriminating ten motions using real time learning method', Proc. IEEE Int. Conf. Systems, Man and Cybernetics, 1999, p. 153–158.
    13. 13)
      • G. Cheron , J. Draye , M. Bourgeios , G. Libert . A dynamic neural network identification of electromyography and arm trajectory relationship during complex movements. IEEE Trans. Biomed. Eng. , 552 - 558
    14. 14)
      • Naik, G.R., Kumar, D.K., Palaniswami, M.: `Identification of independent biological sensors-electromyogram example', Proc. 13th Int. Conf. Eng. Med. Biol. Society, September 2008, p. 1112–1115.
    15. 15)
      • S. Makeig , T. Jung , A. Bell , T. Sejnowski . Independent component analysis of electroencephalographic data. Adv. Neural Info. Process. Syst. , 145 - 151
    16. 16)
      • X. Zhang , X. Chen , Z. Zhao , T. Youqiang , T. Yang , V. Lantz , Q. Wang . Research on gesture definition and electrode placement in pattern recognition of hand gesture action SEMG. ICMB , 33 - 40
    17. 17)
      • K.M. Zardoshti , B.C. Wheeler , K. Badie , R.M. Hashemi . EMG feature evaluation for movement control of upper extremity prostheses. IEEE Trans. Rehab. Eng. , 1267 - 1271
    18. 18)
      • Oakley, I., Angesleva, J., Hughes, S., O'Modhrain, S.: `Tilt and feel: scrolling with vibrotactile display', Proc. EuroHaptics, 2004.
    19. 19)
      • F. Felici , A. Rosponi , P. Sbriccoli , G.C. Filligoi , L. Fattorini , M. Marchetti . Linear and non-linear analysis of surface electromyograms in weightlifters. Eur. J. Appl. Physiol. , 4 , 337 - 342
    20. 20)
      • C.J.D. Luca . Physiology and mathematics of myoelectric signals. IEEE Trans. Biomed. Eng. , 6 , 313 - 325
    21. 21)
      • K. Engelhart , B. Hudgins , P. Parker , M. Stevenson . Classification of the myoelectric signal using time-frequency based representations. Med. Eng. Phys. , 431 - 438
    22. 22)
      • Jung, T., Makeig, S., Lee, T., McKeon, M., Brown, G., Bell, A., Sejnowski, T.: `Independent component analysis of biomedical signals', Proc. Second Int. Workshop Independent Component Analysis and Blind Signal Separation, 2001, p. 633–644.
    23. 23)
      • A. Hyvarinen , E. Oja . (2006) Fast fixedpoint algorithm for ICA, The Fast ICA Matlab software package.
    24. 24)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-spr.2007.0211
Loading

Related content

content/journals/10.1049/iet-spr.2007.0211
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address