A new decoupling method for phased arrays in magnetic resonance imaging: an experimental approach

Access Full Text

A new decoupling method for phased arrays in magnetic resonance imaging: an experimental approach

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Science, Measurement & Technology — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

A new decoupling method for magnetic resonance imaging (MRI) phased arrays is studied by experimental measurements. A laboratory measurement setup is built to characterise the signal coupling paths and their coupling strengths. A new concept, the receiving mutual impedance, is introduced to measure the coupled signals between the phased array elements. Measured values of the receiving mutual impedances for a typical two-element surface-coil array are obtained and used in other experiments to find the uncoupled voltages from the received voltages. Results show that the new decoupling method is both accurate and robust over a wide frequency range. Comparison of the uncoupled voltages with the actual ideal uncoupled voltages confirms that if the position of the signal source is known, almost error-free uncoupled voltages can be obtained. The errors resulted from a change of the position of the signal source are also measured and it is found that they generally increase with the deviation of the signal source from its position where the receiving mutual impedances are measured. The maximum % error of the uncoupled voltages is found to be below 10% when the signal source changes its position over a distance of half the length of a surface coil. Over this distance change, the signal isolation between the two surface coils is found to be at least 20 dB, whereas the maximum is more than 300 dB. The results demonstrate the effectiveness and the feasibility of the new decoupling method for use in MRI phased arrays.

Inspec keywords: coils; arrays; biomedical equipment; biomedical MRI

Other keywords: signal coupling paths; coupling strength; magnetic resonance imaging; decoupling method; MRI phased arrays; two-element surface-coil array; mutual impedance

Subjects: Medical magnetic resonance imaging and spectroscopy; Biomedical magnetic resonance imaging and spectroscopy; Patient diagnostic methods and instrumentation; Biomagnetism

References

    1. 1)
      • H.T. Hui . An effective compensation method for the mutual coupling effect in phased arrays for magnetic resonance imaging. IEEE Trans. Antennas Propag. , 11 , 3576 - 3583
    2. 2)
      • H.T. Hui , B.K. Li , S. Crozier . A new decoupling method for quadrature coils in magnetic resonance imaging. IEEE Trans. Biomed. Eng. , 10 , 2114 - 2116
    3. 3)
      • M.A. Griswold , P.M. Jakob , R.M. Heidemann . Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn. Reson. Med. , 6 , 1202 - 1210
    4. 4)
      • R.F. Lee , R.O. Giaquinto , C.J. Hardy . Coupling and decoupling theory and its application to the MRI phased array. Magn. Reson. Med. , 1 , 203 - 213
    5. 5)
      • H.T. Hui . Improved compensation for the mutual coupling effect in a dipole array for direction finding. IEEE Trans. Antennas Propag. , 9 , 2498 - 2503
    6. 6)
      • Q.X. Yang , J.H. Wang , C.M. Collins . Phantom design method for high-field MRI human systems. Mag. Reson. Med. , 5 , 1016 - 1020
    7. 7)
      • R.E. Collin , F.J. Zucker . (1968) Antenna theory, Part II.
    8. 8)
      • H.T. Hui . A new definition of mutual impedance for application in dipole receiving antenna arrays. IEEE Antennas Wirel. Propag. Lett. , 1 , 364 - 367
    9. 9)
      • H.T. Hui , H.P. Low , T.T. Zhang , Y.L. Lu . Receiving mutual impedance between two normal-mode helical antennas (NMHAs). IEEE Antennas Propag. Mag. , 92 - 96
    10. 10)
      • P.B. Roemer , W.A. Edelstein , C.E. Hayes , S.P. Souza , O.M. Mueller . The NMR phased-array. Magn. Reson. Med. , 2 , 192 - 225
    11. 11)
      • X.Z. Zhang , A. Webb . Design of a capacitively decoupled transmit/receive NMR phased array for high field microscopy at 14.1T. J. Magn. Reson. , 1 , 149 - 155
    12. 12)
      • J.M. Jin . (1999) Electromagnetic analysis and design in magnetic resonance imaging.
    13. 13)
      • D.K. Sodickson , W.J. Manning . Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn. Reson. Med. , 591 - 603
    14. 14)
      • K.P. Pruessmann , M. Weiger , M.B. Scheidegger , P. Boesiger . SENSE: sensitivity encoding for fast MRI. Magn. Reson. Med. , 952 - 962
    15. 15)
      • Z.P. Liang , P.C. Lauterbur . (2000) Principles of magnetic resonance imaging.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-smt_20080033
Loading

Related content

content/journals/10.1049/iet-smt_20080033
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading