access icon free Modified AC standstill method for PMSM d - q axis inductances measurement

This study reports a modified AC standstill method (ACSM) for the axis inductances measurement of permanent magnet synchronous motors (PMSMs), which is free of locked tooling. Based on the voltage function, the axis inductances of a PMSM are derived from the ACSM under the two same phase (TSP) condition through the Laplace transform. The inductance values of the studied external rotor PMSM are measured by this reported TSP ACSM, which are also compared with the DC standstill and the previous ACSM tests. During the process of the TSP ACSM measurement, the voltage source inverter of the motor provides three phase excitation signals which can produce self-saturation and cross-saturation. The theoretical analysis and experimental measurement results validate the accuracy of this reported method.

References

    1. 1)
      • 6. Dutta, R., Rahman, M. F.: ‘A comparative analysis of two test methods of measuring d - and q -axes inductances of Interior permanent-magnet machine’, IEEE Trans. Magn., 2006, 42, pp. 37123718.
    2. 2)
      • 4. Tang, R.: ‘Modern permanent magnet machines-theory and design’ (China Machine Press, China, 2011, 1st Edn.), pp. 424434, (in Chinese).
    3. 3)
      • 14. Ertan, H.B., Sahin, I.: ‘Evaluation of inductance measurement methods for PM machines’. IEEE in Int. Conf. Electri. Mach., Marseille, France, 2012, pp. 16721678.
    4. 4)
      • 7. Dang, D. Q., Rafaq, M. S., Choi, H. H., et al: ‘Online parameter estimation technique for adaptive control applications of Interior PM synchronous motor drives’, IEEE Trans. Ind. Electron., 2016, 63, pp. 14381449.
    5. 5)
      • 8. Hamida, M.A., De, L.J, Glumineau, A., et al: ‘An adaptive interconnected observer for sensorless control of PM synchronous motors with online parameter identification’, IEEE Trans. Ind. Electron., 2013, 60, pp. 739748.
    6. 6)
      • 2. Liu, X., Chen, H., Zhao, J., et al: ‘Research on the performances and parameters of Interior PMSM used for electric vehicles’, IEEE Trans. Ind. Electron., 2016, 63, pp. 35333545.
    7. 7)
      • 3. Fu, R., Dou, M.H.: ‘D-axis and Q-axis inductance calculation and experimental research on Interior permanent magnet synchronous motors for EV’, Trans. China Electr. Technol., 2014, 29, pp. 3037, (in Chinese).
    8. 8)
      • 13. Stumberger, B., Kreca, B., Hribernik, B.: ‘Determination of parameters of synchronous motor with permanent magnets from measurement of load conditions’, IEEE Trans. Energy Convers., 1999, 14, pp. 14131416.
    9. 9)
      • 11. Mwasilu, F., Jung, J. W.: ‘Enhanced fault-tolerant control of Interior PMSMs based on an adaptive EKF for EV traction applications’, IEEE Trans. Power Electr., 2016, 31, pp. 57465758.
    10. 10)
      • 10. Yu, Y., Chen, Y., Bi, Y., et al: ‘Adaptive control of negative-saliency PMSM based on online parameter identification’. IECON 2016 - 42nd Annu Conf. of the IEEE Indu.Electron. Soc., Florence, Italy, 2016, pp. 26602665.
    11. 11)
      • 18. Kallio, S., Karttunen, J., Peltoniemi, P., et al: ‘Determination of the inductance parameters for the decoupled d-q model of double-star permanent magnet synchronous machines’, IET Electr. Power Appl., 2014, 8, pp. 3949.
    12. 12)
      • 16. Hasni, M., Touhami, O., Ibtiouen, R., et al: ‘Estimation of synchronous machine parameters by standstill tests’, Math. Comput. Simul., 2010, 81, pp. 277289.
    13. 13)
      • 15. Gao, Y.T., Qu, R.H., Liu, Y.: ‘An improved AC standstill method for inductance measurement of Interior permanent magnet synchronous motors’. IEEE in Int. Conf. Electri. Mach.Syst.(ICEMS), Busan, 2013, pp. 927931.
    14. 14)
      • 12. Yang, Z., Jin, T., Zhang, C., et al: ‘Determination of q-axis and d-axis armature reaction reactance of permanent magnet synchronous motor using loading magnetic fields’, Ship. Eng., 2015, 37, pp. 5457, (in Chinese).
    15. 15)
      • 5. Lara, J., Xu, J., Chandra, A.: ‘Effects of rotor position error in the performance of field oriented controlled PMSM drives for electric vehicle traction applications’, IEEE Trans. Ind. Electron., 2016, 63, pp. 47384751.
    16. 16)
      • 17. Yue, S., Fan, Y.: ‘Hierarchical direct yaw-moment control system design for In-wheel motor driven electric vehicle’, Int. J. Autom. Technol., 2018, 19, pp. 695703.
    17. 17)
      • 9. Shi, Y., Sun, K., Huang, L., et al: ‘Online identification of permanent magnet flux based on extended kalman filter for IPMSM drive with position sensorless control’, IEEE Trans. Ind. Electron., 2012, 59, pp. 41694178.
    18. 18)
      • 1. Wu, Z.B., Ma, Q.J., Li, C.Y.: ‘Performance investigation and analysis of market-oriented low-speed electric vehicles in China’, J. Clean Prod., 2015, 91, pp. 305312.