http://iet.metastore.ingenta.com
1887

access icon openaccess Time-efficient BER estimation approach using jitter characteristics for HBC channel

Loading full text...

Full text loading...

/deliver/fulltext/iet-smt/12/1/IET-SMT.2016.0257.html;jsessionid=1bjby2b2j15c5.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fiet-smt.2016.0257&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Wegmueller, M.S., Oberle, M., Felber, N., et al: ‘Signal transmission by galvanic coupling through the human body’, IEEE Trans. Instrum. Meas., 2010, 59, (4), pp. 963969.
    2. 2)
      • 2. Bronzino, J.: ‘Biomedical engineering’ (CRC Press, 1995), pp. 1011.
    3. 3)
      • 3. Pun, S.H., Gao, Y.M., Mak, P.U., et al: ‘Quasi-static modeling of human limb for intra-body communications with experiments’, IEEE Trans. Inf. Technol. Biomed., 2011, 15, (6), pp. 870876.
    4. 4)
      • 4. Lucev, Z., Krois, I., Cifrek, M.: ‘Intrabody communication in biotelemetry’, Wearable Auton. Biomed. Devices Syst. Smart Environ. (Lect. Notes Electr. Eng.), 2010, 75, pp. 351368.
    5. 5)
      • 5. Zimmerman, T.G.: ‘Personal area networks: near-field intra-body communication’, IBM Syst. J., 1996, 35, (3-4), pp. 609617.
    6. 6)
      • 6. Handa, T., Shoji, S., Ike, S., et al: ‘A very low-power consumption wireless ECG monitoring system using body as a signal transmission medium’. Proc. Int. Conf. Transducers Solid-State Sensors Actuators, Chicago, USA, June 1997, pp. 10031007.
    7. 7)
      • 7. Ogasawara, T., Sasaki, A., Fujii, K., et al: ‘Human body communication based on magnetic coupling’, IEEE Trans. Antennas Propag., 2014, 62, (2), pp. 804813.
    8. 8)
      • 8. Hwang, J.H., Kang, T.W., Park, S.O., et al: ‘Empirical channel model for human body communication’, IEEE Antennas Wirel. Propag. Lett., 2015, 14, pp. 694697.
    9. 9)
      • 9. Tsou, Y.L., Gong, C.A., Cheng, N.C., et al: ‘Integrated biosensing platform based on a 1.74 mW −90 dbm sensitivity dual-mode-operation receiver for IEEE 802.15.6 human body communication standard’, IEEE Sens. J., 2015, 15, (6), pp. 33173327.
    10. 10)
      • 10. Kibret, B., Seyedi, M., Lai, D.T.H., et al: ‘Investigation of Galvanic-coupled intrabody communication using the human body circuit model’, IEEE J. Biomed. Health Inf., 2014, 18, (4), pp. 11961206.
    11. 11)
      • 11. Callejon, M.A., Tosina, J.R., Hernandez, D.N., et al: ‘Galvanic coupling transmission in intrabody communication: a finite element approach’, IEEE Trans. Biomed. Eng., 2014, 61, (3), pp. 775783.
    12. 12)
      • 12. Bae, J., Yoo, H.: ‘The effects of electrode configuration on body channel communication based on analysis of vertical and horizontal electric dipoles’, IEEE Trans. Microw. Theory Tech., 2015, 63, (4), pp. 14091420.
    13. 13)
      • 13. Callejon, M.A., Tosina, J.R., Hernandez, D.N., et al: ‘Measurement issues in Galvanic intrabody communication: influence of experimental setup’, IEEE Trans. Biomed. Eng., 2015, 62, (11), pp. 27242732.
    14. 14)
      • 14. Ntouni, G.D., Lioumpas, A.S., Nikita, K.S.: ‘Reliable and energy-efficient communication for wireless biomedical implant systems’, IEEE J. Biomed. Health Inf., 2014, 18, (6), pp. 18481856.
    15. 15)
      • 15. Hyoung, C.H., Hwang, J.H., Kang, S.W., et al: ‘A feasibility study on the adoption of human body communication for medical service’, IEEE Trans. Circuits Syst. II, Express Briefs, 2015, 62, (2), pp. 169173.
    16. 16)
      • 16. Strassberg, D.: ‘Eyeing jitter: shaking out why signals shake’, Eur. Ed., 2003, 48, (10), pp. 4252.
    17. 17)
      • 17. Li, M.P.: ‘Jitter, noise, and signal integrity at high-speed’ (Prentice-Hall, 2007), Chapter 4.
    18. 18)
      • 18. Eng, J.: ‘Sample size estimation: how many individuals should be studied?’, Radiology, 2003, 227, (2), pp. 309313.
    19. 19)
      • 19. Li, J.W., Chen, X.M., Pun, S.H., et al: ‘Bit error rate estimation for galvanic-type intra-body communication using experimental eye-diagram and jitter characteristics’. Proc. 35th Annual Int. Conf. IEEE EMBS, Osaka, Japan, July 2013, pp. 51955198.
    20. 20)
      • 20. Chen, X.M., Mak, P.U., Pun, S.H., et al: ‘Study of channel characteristics for Galvanic-type intra-body communication based on a transfer function from a quasi-static field model’, Sensors, 2012, 12, (12), pp. 1643316450.
    21. 21)
      • 21. International Commission on Non-Ionizing Radiation Protection (ICNIRP): ‘Limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz)’, Health Phys., 2010, 99, (6), pp. 818836, Table 5.
    22. 22)
      • 22. Prel, J.D., Hommel, G., Röhrig, B., et al: ‘Confidence interval or p-value? Part 4 of a series on evaluation of scientific publications’, Dtsch. Arzteblatt Int., 2009, 106, (19), pp. 335339.
    23. 23)
      • 23. Proakis, J.G.: ‘Digital communications’ (McGraw-Hill, 2007, 5th edn.), Chapter 4.
    24. 24)
      • 24. Mahmoud, H., Arslan, H.: ‘Error vector magnitude to SNR conversion for nondata-aided receivers’, IEEE Trans. Wirel. Commun., 2009, 8, (5), pp. 26942704.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-smt.2016.0257
Loading

Related content

content/journals/10.1049/iet-smt.2016.0257
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address