External overvoltages constitute a typical cause of faults, damages and interruptions in the electrical networks’ high-voltage transmission lines. In order to protect the lines and their equipment against lightning, overhead ground wires in combination with surge arresters are installed, improving the lightning performance of the system and reducing the annual failure rate. The achievement of low values of earth resistance is an essential requirement, since a good grounding system reduces considerably the corresponding insulation breakdowns. However, the behaviour of surge arresters in relation to the grounding resistance is different, as it depends on the position of the lightning hit. The current work is devoted to the sensitivity analysis of the failure probability of surge arresters with relation to the grounding resistance, investigating concurrently the effect of the arresters’ installation interval and the energy absorption capability.
References
-
-
1)
-
11. Hinrichsen, V.: ‘Metal-oxide surge arresters’ (Fundamentals, Siemens, 2001, 1st edn.).
-
2)
-
10. : ‘IEEE guide for improving the lightning performance of transmission lines’. 1997.
-
3)
-
4. Nakada, K., Yokoyama, S., Yokota, T., Asakawa, A., Kawabata, T.: ‘Analytical study on prevention for distribution arrester outages caused by winter lightning’, IEEE Trans. Power Deliv., 1998, 13, (4), pp. 1399–1404 (doi: 10.1109/61.714514).
-
4)
-
L. Montanes ,
M. Garcia-Gracia ,
M. Sanz ,
M.A. Garcia
.
An improvement for the selection of surge arresters based on the evaluation of the failure probability.
IEEE Trans. Power Deliv.
,
1 ,
123 -
128
-
5)
-
6. Tarchini, J.A., Gimenez, W.: ‘Line surge arrester selection to improve lightning performance of transmission lines’. IEEE Bologna Power Tech Conf., Bologna, Italy, 2003.
-
6)
-
7. Correia, M.T., Festas, J., Milheiras, H., Felizardo, N., Fernadez, M., Sousa, J.: ‘Methodologies for evaluating the lightning performance of transmission lines’. ICOLIM'98 – 4ª Conf. Int. de Trabalhos em Tensão, Lisboa, 1998.
-
7)
-
1. IEEE Working Group on Lightning Performance of Transmission Lines: ‘A simplified method for estimating lightning performance of transmission lines’, IEEE Trans. PAS, 1985, 104, (4), pp. 919–927.
-
8)
-
L.C. Zanetta ,
C.E.M. de Pereira
.
Application studies of line arresters in partial shielded 138-kV transmission lines.
IEEE Trans. Power Deliv.
,
1 ,
95 -
100
-
9)
-
8. : ‘Surge Arresters – Part 4: Metal-oxide surge arresters without gaps for a.c. systems’. .
-
10)
-
I.F. Gonos ,
L. Ekonomou ,
F.V. Topalis ,
I.A. Stathopulos
.
Probability of backflashover in transmission lines due to lightning strokes using Monte-Carlo simulation.
Int. J. Electr. Power Energy Syst.
,
2 ,
107 -
111
-
11)
-
9. ΑΒΒ Buyer's Guide: ‘High voltage surge arresters’ (ABB, 2004, 5.1 edn.).
-
12)
-
12. Christodoulou, C.A., Ekonomou, L., Fotis, G.P., Gonos, I.F., Stathopulos, I.A.: ‘Assessment of surge arrester failure rate and application studies in Hellenic high voltage transmission lines’, Electr. Power Syst. Res., 2010, 80, (2), pp. 176–183 (doi: 10.1016/j.epsr.2009.08.018).
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-smt.2014.0017
Related content
content/journals/10.1049/iet-smt.2014.0017
pub_keyword,iet_inspecKeyword,pub_concept
6
6