Analysis of the voltage harmonic distortion at buses feeding office loads

Analysis of the voltage harmonic distortion at buses feeding office loads

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Science, Measurement & Technology — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The harmonic distortion of the phase-to-neutral voltage at low-voltage buses feeding office load is investigated for various cable configurations, lengths and cross-sections. The investigation is carried out with a software model that was validated with analytical expressions and measurements taken at a real installation. It is shown that the selection of a cable should be based not only on its ampacity and allowable voltage drop but also on its configuration, in order to avoid excessive voltage harmonic distortion. Configurations where the neutral conductor is part of a four-core cable lead to relatively small harmonic distortion, whereas cable configurations where the neutral conductor runs separately cause high-voltage harmonic distortion. In the latter case, the neutral conductor develops a significant voltage with respect to the ground. Increasing the cross-section of the neutral conductor, as the existing standards dictate, may prevent its overloading from zero-sequence harmonic currents but hardly improves the voltage harmonic distortion at the load bus.

References

    1. 1)
      • J.J.M. Desmet , I. Sweertvaegher , G. Vanalme , K. Stockman , R.J.M. Belmans . Analysis of the neutral conductor current in a three-phase supplied network with nonlinear single-phase loads. IEEE Trans. Ind. Appl. , 3 , 587 - 593
    2. 2)
      • G.W. Chang . Characterizing harmonic currents generated by fluorescent lamps in harmonic domain. IEEE Trans. Power Deliv. , 4 , 1583 - 1585
    3. 3)
    4. 4)
      • J.-S. Lai , T.S. Key . Effectiveness of harmonic mitigation equipment for commercial office buildings. IEEE Trans. Ind. Appl. , 4 , 1104 - 1110
    5. 5)
      • NFPA 70, National Electrical Code, 2005 Edition, August 5, 2004; Published by the National Fire Protection Association.
    6. 6)
      • P.-T. Cheng , C.-C. Hou , Y.-F. Huang . Overload prevention. IEEE Ind. Appl. Mag. , 6 , 26 - 34
    7. 7)
    8. 8)
      • Grady, W.M., Mansoor, A., Fuchs, E.F., Verde, P., Doyle, M.: `Estimating the net harmonic currents produced by selected distributed single-phase loads: computers, televisions, and incandescent light dimmers', IEEE PES Winter Meeting, 27–31 January 2002, 2, p. 1090–1094.
    9. 9)
      • D.O. Koval , C. Carter . Power quality characteristics of computer loads. IEEE Trans. Ind. Appl. , 3 , 613 - 621
    10. 10)
      • IEC Standard 60364-1:2005-11, .
    11. 11)
    12. 12)
      • E. Empriz-Santander , A. Domijan , C.W. Williams . A comprehensive harmonic study of electronic ballasts and their effect on a utility's 12 kV, 10 MVA feeder. IEEE Trans. Power Deliv. , 3 , 1591 - 1599
    13. 13)
    14. 14)
    15. 15)
      • A.P. Sakis Meliopoulos . (1988) Power system grounding and transients.
    16. 16)
      • CENELEC Standard HD384.5.523, S2:2001, .
    17. 17)
      • J.P.G. de Abreu , A.E. Emanuel . Induction motor thermal aging caused by voltage distortion and imbalance: loss of useful life and its estimated cost. IEEE Trans. Ind. Appl. , 1 , 12 - 20
    18. 18)
      • A.R. Seidel , F.E. Bisogno , T.B. Marchesan , R.N. do Prado . A practical comparison among high-power-factor electronic ballasts with similar ideas. IEEE Trans. Ind. Appl. , 6 , 1574 - 1583
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-smt.2008.0069
Loading

Related content

content/journals/10.1049/iet-smt.2008.0069
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address