access icon free Phase angle calculation dynamics of type-4 wind turbines in rms simulations during severe voltage dips

To conduct power system simulations with high shares of wind energy, standard wind turbine models, which are aimed to be generic rms models for a wide range of wind turbine types, have been developed. As a common practice of rms simulations, the power electronic interface of wind turbines is assumed to be ideally synchronised, i.e. grid synchronisation (e.g. phase locked loop (PLL)) is not included in simplified wind turbine models. As will be shown in this study, this practice causes simulation convergence problems during severe voltage dips and when the loss of synchronism occurs. In order to provide the simulation convergence without adding complexity to the generic models, a first-order filtering approach is proposed as a phase angle calculation algorithm in the grid synchronisation of the rms type-4 wind turbine models. The proposed approach provides robustness for the simulation of large-scale power systems with high shares of wind energy.

References

    1. 1)
      • 12. Dong, D., Bo, W., Boroyevich, D., et al: ‘Analysis of phase-locked loop low-frequency stability in three-phase grid-connected power converters considering impedance interactions’, IEEE Trans. Ind. Electron., 2015, 62, (1), pp. 310321.
    2. 2)
      • 3. ENTSO-E: ‘Network code for requirements for grid connection applicable to all generators (NC RfG)’, European Network of Transmission System Operators for Electricity ENTSO-E, 2015.
    3. 3)
      • 2. Asmine, M., Brochu, J., Fortmann, J., et al: ‘Model validation for wind turbine generator models’, IEEE Trans. Power Syst., 2011, 26, (3), pp. 17691782.
    4. 4)
      • 11. Teodorescu, R., Liserre, M., Rodriguez, P.: ‘Grid converters for photovoltaic and wind power systems’ (Wiley Press, 2011).
    5. 5)
      • 5. Erlich, I., Shewarega, F., Engelhardt, S., et al: ‘Effect of wind turbine output current during faults on grid voltage and the transient stability of wind parks’. IEEE Power and Energy Society General Meeting, July 2009, pp. 18.
    6. 6)
      • 7. Fortmann, J., Engelhardt, S., Kretschmann, J., et al: ‘New generic model of DFG-based wind turbines for RMS-type simulation’, IEEE Trans. Energy Convers., 2014, 29, (1), pp. 110118.
    7. 7)
      • 1. IEC 61400-27-1 Ed. 1: ‘Wind turbines – part 27-1: electrical simulation models – wind turbines’, February 2015.
    8. 8)
      • 9. Blaabjerg, F., Teodorescu, R., Liserre, M., et al: ‘Overview of control and grid synchronization for distributed power generation systems’, IEEE Trans. Ind. Electron., 2006, 53, (5), pp. 13981409.
    9. 9)
      • 10. Yazdani, A., Iravani, R.: ‘Voltage-sourced converters in power systems’ (IEEE/Wiley, 2010).
    10. 10)
      • 4. Goksu, O., Teodorescu, R., Bak, C.L., et al: ‘Instability of wind turbine converters during current injection to low voltage grid faults and PLL frequency based stability solution’, IEEE Trans. Power Syst., 2014, 29, (4), pp. 16831691.
    11. 11)
      • 6. Weise, B.: ‘Impact of K-factor and active current reduction during fault-ride-through of generating units connected via voltage-sourced converters on power system stability’, IET Renew. Power Gener., 2015, 9, (1), pp. 2536.
    12. 12)
      • 8. Larsen, E.V., Klodowski, A.M., Barker, S.A.: ‘Method and systems for operating a wind turbine’, US 8,046,109 B2, 25 October 2011.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2015.0501
Loading

Related content

content/journals/10.1049/iet-rpg.2015.0501
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address