Back-to-back starting is a widely accepted starting method for pumped storage units. A back-to-back starting model of pumped storage units was built using the ElectroMagnetic Transients Program including DC (EMTDC) software package. The short-circuit fault during back-to-back starting was investigated for the first time. The starting process was simulated and compared with real data from a pumped storage power plant in northeast China. The rotor speed and the effect of resistance during fault period were also discussed. The results showed that the fault current has significant magnitude and low-frequency characteristic. Recommendations were provided to realise secure and reliable fault clearance during back-to-back starting based on the fault characteristics and real de-excitation test results of the pumped storage power plant.
References
-
-
1)
-
4. Wang, F., Jiang, J.: ‘A novel static frequency converter based on multilevel cascaded H-bridge used for the startup of synchronous motor in pumped-storage power station’, Energy Convers. Manage., 2011, 52, pp. 2085–2091 (doi: 10.1016/j.enconman.2010.12.018).
-
2)
-
3. Xiaoyuan, W., Na, R.: ‘Simulation of asynchronous starting process of synchronous motors based on Matlab/Simulink’, IEEE Electr. Mach. Syst., 2003, 2, pp. 684–687.
-
3)
-
2. Tuohy, A, O'Malley, M.: ‘Pumped storage in systems with very high wind penetration’, Energy Policy, 2011, 39, pp. 1965–1974 (doi: 10.1016/j.enpol.2011.01.026).
-
4)
-
12. Lipo, T.A.: ‘Analysis of synchronous machines’ (CRC Press Inc., Salem, MA, 2012).
-
5)
-
7. Osburn, G.D., Atwater, P.L.: ‘Design and testing of a back-to-back starting system for pumped storage hydrogenerators at Mt. Elbert Power plant’, IEEE Trans. Energy Convers., 1992, 7, (2), pp. 280–288 (doi: 10.1109/60.136222).
-
6)
-
9. Concordia, C., Brown, P.G., Miller, W.J., Wuosmaa, L.: ‘Synchronous starting of motor from generator of small capacity’, IEEE Trans. Power Appar. Syst., 1967, PAS-86, (10), pp. 1215–1226 (doi: 10.1109/TPAS.1967.291896).
-
7)
-
14. Wamkeue, R., Kamwa, I., Dai-Do, X.: ‘Numerical modeling and simulation of unsymmetrical transients on synchronous machines with neutral included’, Electr. Mach. Power Syst., 1998, 26, (1), pp. 93–108 (doi: 10.1080/07313569808955810).
-
8)
-
13. Hwang, H.H.: ‘Transient analysis of simultaneous unbalanced short circuits of synchronous machines’, IEEE Trans. Energy Convers., 1971, PAS-90, pp. 1815–1821.
-
9)
-
11. Shiwu, X., Jianhui, L., Xiaojuan, K.: ‘The coordination of back-to-back starting and protections for pumped storage units’. Power and Energy Engineering Conf. (APPEEC), Asia-Pacific, 2012, pp. 1–4.
-
10)
-
10. Rajamani, K., Hariharan, M.V.: ‘Synchronous starting of synchronous machine’, Electr. Mach. Power Syst., 1993, 21, pp. 647–661 (doi: 10.1080/07313569308909690).
-
11)
-
5. Magsaysay, G., Schuette, T., Fostiak, R.: ‘Use of a static frequency converter for rapid load response in pumped-storage plants’, IEEE Trans. Energy Convers., 1995, 10, (4), pp. 694–699 (doi: 10.1109/60.475841).
-
12)
-
1. Rodica, L.: ‘Power system flexibility with electricity storage technologies: a technical-economic assessment of a large-scale storage facility’, Int. J. Electr. Power Energy Syst., 2012, 42, (1), pp. 542–552 (doi: 10.1016/j.ijepes.2012.04.058).
-
13)
-
6. Konidaris, D.N.: ‘Investigation of back-to-back starting of pumped storage hydraulic generating units’, IEEE Trans. Energy Convers., 2002, 17, (2), pp. 273–277 (doi: 10.1109/TEC.2002.1009480).
-
14)
-
8. Karmaker, H., Mi, C.: ‘Improving the starting performance of large salient-pole synchronous machines’, IEEE Trans. Magn., 2004, 40, (4), pp. 1920–1927 (doi: 10.1109/TMAG.2004.831003).
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-rpg.2013.0419
Related content
content/journals/10.1049/iet-rpg.2013.0419
pub_keyword,iet_inspecKeyword,pub_concept
6
6