Methodology of calculating droop coefficients for stabilising DC voltage in VSC-MTDC system against disturbances

Methodology of calculating droop coefficients for stabilising DC voltage in VSC-MTDC system against disturbances

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The application of droop control in the voltage-source converter-based multi-terminal direct current (VSC-MTDC) system has been previously proposed in the literature. However, how to determine the droop coefficients to stabilise the DC voltage is still the key issue to concern and research. This study presents a novel calculation methodology for droop coefficients in the case of outage or power step disturbance on any converter station. The overall design objective is to minimise the DC voltage deviation between pre- and post-disturbance, depicted with a quadratic programming model. In addition, the selection method of the optimal DC voltage signal for droop controllers is developed in both cases of communication failure and communication normal. Based on the calculated droop coefficients and selected DC voltage signal, the power coordinated control among the converter stations is implemented to stabilise the DC voltage of the post-disturbance system quickly. Case studies are conducted on the Nordic 32 and New England system, respectively. The simulation results show that the proposed methodology for droop coefficients can significantly reduce the steady-state DC voltage deviations without the limitation of preassigning the maximum allowable DC voltage deviation, compared to the methodologies existing in the literature.

http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2018.5058
Loading

Related content

content/journals/10.1049/iet-gtd.2018.5058
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address