access icon free Adaptability of phase selectors based on phase-to-phase superimposed currents when confronting cross-voltage faults in mixed-voltage quadruple-circuit line system

For the mixed-voltage quadruple-circuit transmission lines on the same tower, its special construction form makes the cross-voltage faults, i.e. multi-circuit faults that occur between different voltage level systems, easy to occur. Although the phase selector based on phase-to-phase superimposed currents (PTPSC) shows excellent performance in the single transmission line, it cannot guarantee to identify faulted phases when confronting cross-voltage faults. In this study, the adaptability of phase selectors based on PTPSC is analysed and a new method of phase selection is put forward. First, the PTPSC measured by the relay can be obtained on the basis of cross-voltage short-circuit calculation. Then, the influencing factors and possible selection results are comprehensively analysed, and the corresponding measure has been proposed. Finally, a fault model of mixed-voltage quadruple-circuit transmission lines is constructed in PSCAD and simulation results agree well with the theoretical analysis, verifying the validity of this method.

References

    1. 1)
      • 11. Sun, S.J., Tai, N.L., Bo, Z.Q.: ‘The study of ground distance protection of 500 kV quadruple-circuit transmission lines on the same tower’. 2008 43rd Int. Universities Power Engineering Conf., Padova, Italy, September 2008, pp. 16.
    2. 2)
      • 16. Khorashadi-Zadeh, H.: ‘Artificial neural network approach to fault classification for double circuit transmission lines’. Proc. 2004 IEEE Transmission and Distribution Conf., Sao Paulo, Brazil, November 2004, pp. 859862.
    3. 3)
      • 7. Fan, C.J., Xu, K., Liu, Q.: ‘Short-circuit current calculation method for partial coupling transmission lines under different voltage levels’, Int. J. Electr. Power Energy Syst., 2016, 78, pp. 647654.
    4. 4)
      • 20. Liu, X., Huang, S.F., Zhang, P.: ‘Adaptability analysis of phase-selector based on sudden-change of phase-phase currents in cross-voltage fault occurred in mixed-voltage four-circuit transmission lines’, Trans. China Electrotech. Soc., 2015, 30, (21), pp. 118126.
    5. 5)
      • 10. Agrasar, M., Uriondo, F., Hernandez, J.R., et al: ‘A useful methodology for analyzing distance relays performance during simple and inter-circuit faults in multi-circuit lines’, IEEE Trans. Power Deliv., 1997, 12, (4), pp. 14651471.
    6. 6)
      • 18. Zeng, G.H., Chen, Q.P., Cai, Z.X., et al: ‘Operation characteristic analysis of same-tower transmission lines and its influence on relay protection’. 2011 4th Int. Conf. on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), Weihai, Shandong, China, July 2011, pp. 944950.
    7. 7)
      • 14. Kale, V. S., Bhide, S.R., Bedekar, P.P.: ‘Faulted phase selection on double circuit transmission line using wavelet transform and neural network’. 2009 Int. Conf. on Power Systems, Kharagpur, India, December 2009, pp. 16.
    8. 8)
      • 17. Li, W., Wang, X.G., Li, Z.Q., et al: ‘A combined phase selector element based on the superimposed sequence components for parallel lines on the same tower’. 2013 IEEE PES Asia-Pacific Power and Energy Engineering Conf. (APPEEC), Kowloon, Hong Kong, December 2013, pp. 16.
    9. 9)
      • 19. Liu, Q., Tai, N.L., Fan, C.J., et al: ‘Fault phase selection scheme for quadruple-circuit transmission lines with asymmetrical parameter based on single-ended electrical quantities’, Trans. China Electrotech. Soc., 2016, 31, (04), pp. 178186..
    10. 10)
      • 13. Zhang, H., Sheng, W.X.: ‘A fault phase selection scheme based on ratio of opposite-direction-current to same-direction-current for parallel lines’. 2014 Int. Conf. on Power System Technology, Chengdu, China, October 2014, pp. 512517.
    11. 11)
      • 6. Huang, S.F., Liu, X., Wang, H.M., et al: ‘Cross-voltage short circuit calculation on mixed-voltage four-circuit lines system’, Proc. CSEE, 2016, 36, (04), pp. 9931001.
    12. 12)
      • 1. Huang, A.H., Zheng, X., Qian, G.Z.: ‘Application of technology of constructing multiple circuits on the same tower’, East China Electr. Power, 2006, 34, (8), pp. 6063..
    13. 13)
      • 8. Liu, L., Fan, C.J..: ‘Fault calculation method of four transmission lines on same tower of different voltage grades’, Proc. CSU-EPSA, 2011, 23, (02), pp. 110115.
    14. 14)
      • 5. Zheng, T., Zhang, J.Q., Wu, D., et al: ‘Cross-voltage short circuit calculation for mixed-voltage quadruple-circuit lines on the same tower’, IET Gener. Transm. Distrib., 2017, 11, (9), pp. 23422350.
    15. 15)
      • 9. Guo, P.Y., Yu, Z.G., Tai, N.L.: ‘Study on a new earth-fault distance protection for four-circuit transmission lines on the same tower’. Advanced Materials Research, 2013, 706–708, pp. 15741579.
    16. 16)
      • 4. Horton, P., Swain, S.: ‘Using superimposed principles (delta) in protection techniques in an increasingly challenging power network’. 2017 70th Annual Conf. for Protective Relay Engineers (CPRE), College Station, TX, USA, April 2017, pp. 112.
    17. 17)
      • 15. Jones, M.S., Thomas, D.W.P., Christopoulos, C.: ‘A non-pilot phase selector based on superimposed components for protection of double circuit lines’, IEEE Trans. Power Deliv., 1997, 12, (04), pp. 14391444.
    18. 18)
      • 12. Tian, S., Liu, F.F.: ‘An integrated fault phase selection scheme for double circuit lines on the same tower’. Applied Mechanics and Materials, 2014, 668–669, pp. 657660.
    19. 19)
      • 3. Zhang, B.H., Yin, X.G.: ‘Power system protective relaying’ (China Electric Power Press, Beijing, China, 2010, 3rd edn.), pp. 104105..
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2017.1956