Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

access icon free System-level dynamic phasor models of hybrid AC/DC microgrids suitable for real-time simulation and small signal analysis

This study develops a system-level dynamic phasor (DP) model of a hybrid AC/DC microgrid. A new definition of DP, based on the multiple frequency shift transformation, is proposed to extend the models of a variety of AC/DC and DC/DC converters. The comprehensive control system is considered in developing the DP model of microgrid. Furthermore, a computational framework for applying this DP model into system-level simulation and small signal analysis (SSA) is given. The DP-based simulation is tested under conditions of environmental disturbances and unbalanced supply voltages. The SSA is performed on the developed DP model to evaluate the voltage stability and harmonic modes of the microgrid. Besides, this DP model shows high potential when implemented in the real-time simulation with larger scale system.

References

    1. 1)
      • 5. Kundur, P.: ‘Power system stability and control’ (McGraw-Hill Press, New York, NY, USA, 1994, 1st edn.).
    2. 2)
      • 9. Liu, C., Bose, A., Tian, P.: ‘Modeling and analysis of HVDC converter by three-phase dynamic phasor’, IEEE Trans. Power Deliv., 2014, 29, (1), pp. 312.
    3. 3)
      • 2. Shu, Y., Chen, G., Yu, Z., et al: ‘Characteristic analysis of UHVAC/DC hybrid power grids and construction of power system protection’, CSEE J. Power Energy Syst., 2017, 3, (4), pp. 325333.
    4. 4)
      • 21. Robert, W.E., Dragan, M.: ‘Fundamentals of power electronics: part 2: converter dynamics and control’ (CRC Press, Boca Raton, FL, USA, 2001, 2nd edn.).
    5. 5)
      • 24. Papathanassiou, S., Hatziargyriou, N., Strunz, K.: ‘A benchmark low voltage microgrid network’. CIGRE Symp., Athens, Greece, 2005, pp. 15.
    6. 6)
      • 8. Daryabak, M., Filizadeh, S., Jatskevich, J., et al: ‘Modeling of LCC-HVDC systems using dynamic phasors’, IEEE Trans. Power Deliv., 2014, 29, (4), pp. 19891998.
    7. 7)
      • 18. Soultanis, N.L., Papathanasiou, S.A., Hatziargyriou, N.D.: ‘A stability algorithm for the dynamic analysis of inverter dominated unbalanced LV microgrids’, IEEE Trans. Power Syst., 2007, 22, (1), pp. 294304.
    8. 8)
      • 12. Liu, C., Zhao, Y., Wang, C., et al: ‘Superposition feature of the switching functions for the dynamic phasor model of the converters under commutation failure’, IET Gener. Transm. Distrib., 2015, 9, (12), pp. 14481454.
    9. 9)
      • 20. Huang, Y., Chapariha, M., Therrien, F., et al: ‘A constant-parameter voltage-behind-reactance synchronous machine model based on shifted-frequency analysis’, IEEE Trans. Energy Convers., 2014, 30, (2), pp. 761771.
    10. 10)
      • 7. Watson, N., Arrillaga, J.: ‘Power systems electromagnetic transients simulation’ (IET Press, London, UK, 2003, 1st edn.).
    11. 11)
      • 6. Singh, M.: ‘Protection coordination in distribution systems with and without distributed energy resources – a review’, Protect. Control Mod. Power Syst., 2017, 2, (1), pp. 2743.
    12. 12)
      • 1. Unamuno, E., Barrena, J.A.: ‘Hybrid ac/dc microgrids – part I: review and classification of topologies’, Renew. Sustain. Energy Rev., 2015, 52, pp. 12511259.
    13. 13)
      • 11. Pavlovic, T., Bjazic, T., Ban, Z.: ‘Simplified averaged models of DC–DC power converters suitable for controller design and microgrid simulation’, IEEE Trans. Power Electron., 2012, 28, (7), pp. 32663275.
    14. 14)
      • 17. Miao, Z., Piyasinghe, L., Khazaei, J., et al: ‘Dynamic phasor-based modeling of unbalanced radial distribution systems’, IEEE Trans. Power Syst., 2015, 30, (6), pp. 31023109.
    15. 15)
      • 19. Zhang, P., Marti, J.R., Dommel, H.W.: ‘Shifted-frequency analysis for EMTP simulation of power-system dynamics’, IEEE Trans. Circuits Syst. I Regul. Pap., 2010, 57, (9), pp. 25642574.
    16. 16)
      • 14. Jovcic, D., Jamshidifar, A.A.: ‘Phasor model of modular multilevel converter with circulating current suppression control’, IEEE Trans. Power Deliv., 2015, 30, (4), pp. 18891897.
    17. 17)
      • 10. Stefanov, P.C., Stankovic, A.M.: ‘Modeling of UPFC operation under unbalanced conditions with dynamic phasors’, IEEE Power Eng. Rev., 2007, 22, (3), pp. 5959.
    18. 18)
      • 13. Zhong, Q., Lin, L., Wang, G., et al: ‘Harmonic analysis model for voltage source converter under unbalanced conditions’, IET Gener. Transm. Distrib., 2015, 9, (1), pp. 1221.
    19. 19)
      • 22. Zhu, M., Hang, L., Li, G., et al: ‘Protected control method for power conversion interface under unbalanced operating conditions in AC/DC hybrid distributed grid’, IEEE Trans. Energy Convers., 2016, 31, (1), pp. 5768.
    20. 20)
      • 3. Guo, W., Mu, L.: ‘Control principles of micro-source inverters used in microgrid’, Protect. Control Mod. Power Syst., 2016, 1, (1), pp. 511.
    21. 21)
      • 15. Lu, X., Lin, W., Wen, J., et al: ‘Dynamic phasor modelling and operating characteristic analysis of half-bridge MMC’. Power Electronics and Motion Control Conf., Hefei, China, July 2016, pp. 26152621.
    22. 22)
      • 16. Li, T., Gole, A.M., Zhao, C.: ‘Harmonic instability in MMC-HVDC converters resulting from internal dynamics’, IEEE Trans. Power Deliv., 2016, 31, (4), pp. 17381747.
    23. 23)
      • 4. Eghtedarpour, N., Farjah, E.: ‘Power control and management in a hybrid AC/DC microgrid’, IEEE Trans. Smart Grid, 2014, 5, (3), pp. 14941505.
    24. 24)
      • 23. Ji, W., Wang, K., Li, G., et al: ‘A real-time simulation algorithm for power electronics circuit considering multiple switching events and its application on PXI platform’. 2016 IEEE 16th Int. Conf. on Environment and Electrical Engineering (EEEIC), Florence, Italy,June 2016, pp. 16.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2017.1319
Loading

Related content

content/journals/10.1049/iet-gtd.2017.1319
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field