access icon free Effects of voltage harmonic on losses and temperature rise in distribution transformers

The effects of harmonic pollution in the power system on distribution transformer losses and temperature rise have become an increasing concern. The pollution can be in the form of current and/or voltage harmonics present in the supply networks. Since the impact of voltage harmonics has hardly been investigated, this study examines the effects of distorted voltage excitation on oil-filled distribution transformers. Short-circuit and open-circuit tests were conducted on two distribution transformers. The results revealed significant increase in both losses and temperature. An equation is developed to quantify the power loss. This study also derives an equation to evaluate the resistance corresponding to the eddy-current loss.

Inspec keywords: eddy current losses; distribution networks; transformer oil; power system harmonics; power transformer testing

Other keywords: current harmonics; oil-filled distribution transformer; eddy-current loss; voltage harmonic effect; open-circuit testing; distribution transformers; power system; distorted voltage excitation; harmonic pollution effect; supply network; short-circuit testing

Subjects: Organic insulation; Distribution networks; Power supply quality and harmonics; Transformers and reactors

References

    1. 1)
      • 10. Fuchs, E.F., Roesler, D.J., Kovacs, K.P.: ‘Aging of electrical appliances due to harmonics of the power system's voltage’, IEEE Trans. Power Deliv., 1986, 1, pp. 301307.
    2. 2)
      • 14. Kweon, D.J., Koo, K.S., Woo, J.W., et al: ‘A study on the hot spot temperature in 154 kV power transformers’, J. Electr. Eng. Technol., 2012, 7, pp. 312319.
    3. 3)
      • 8. So, E., Arseneau, R., Hanique, E.: ‘No-load loss measurements of power transformers under distorted supply voltage waveform conditions’, IEEE Trans. Instrum. Meas., 2003, 52, pp. 429432.
    4. 4)
      • 20. Dao, T., Phung, B.T.: ‘A comparative study of power loss caused by voltage harmonics in aged transformer’. 2016 Int. Conf. Condition Monitoring and Diagnosis (CMD), Xi'an, China, 2016.
    5. 5)
      • 19. Olivares-Galvan, J.C., Escarela-Perez, R., León, F.D., et al: ‘Separation of core losses in distribution transformers using experimental methods’, IEEE Can. J. Electr. Comput. Eng., 2010, 35, (1), pp. 3339.
    6. 6)
      • 22. So, E., Arseneau, R., Hanique, R.: ‘No-load loss measurements of power transformers under distorted supply voltage waveform conditions’. Conf. Precision Electromagnetic Measurements, Ottawa, Ontario, Canada, 2002.
    7. 7)
      • 12. Masri, S., Azizan, M.M., Jamil, M.K.M.: ‘Measuring temperature rise at transformer core under nonlinear loading’. Int. Conf. on Electrical, Control and Computer Engineering, Pahang, 2011.
    8. 8)
      • 25. Chan, M., Lee, K.K., Fung, M.W.: ‘A case study survey of harmonic currents generated from a computer centre in an office building’, Archit. Sci. Rev., 2007, 50, pp. 274280.
    9. 9)
      • 4. Faiz, J., Ghazizadeh, M., Oraee, H.: ‘Derating of transformers under non-linearload current and non-sinusoidal voltage – an overview’, IET Electr. Power Appl., 2015, 9, (7), pp. 486495.
    10. 10)
      • 30. C57.91: ‘IEEE guide for loading mineral oil-immersed transformers and step-voltage regulators’. 2011.
    11. 11)
      • 28. Ressler, K., Brucker, K., Nagurka, M.: ‘A thermal time-constant experiment’, Int. J. Eng. Educ.’, 2003, 19, pp. 603609.
    12. 12)
      • 11. Separi, F., Samakush, M., Vahabzadeh, A.R.: ‘Assessment of power distribution transformers electrical and thermal parameters in harmonic environments’. 31st Int. Telecommunications Energy Conf., Incheon, 2009.
    13. 13)
      • 3. IEEE Std. 519: ‘IEEE recommended practices and requirements for harmonic control in electrical power systems’. 2014.
    14. 14)
      • 1. Khruslov, L., Rostovikov, M., Shishov, V.: ‘Web-based power quality monitoring system of smart transformer substation RTP-34 MPEI for engineering education’. 8th Int. Scientific Symp. Electric Power Engineering, Stara Lesna, Slovakia, 2015, pp. 400403.
    15. 15)
      • 6. C57.110: ‘IEEE recommended practice for establishing liquid-filled and dry-type power and distribution transformer capability when supplying nonsinusoidal load currents’. 2008.
    16. 16)
      • 13. Radakovic, Z., Feser, K.: ‘A new method for the calculation of the hot-spot temperature in power transformers with ONAN cooling’, IEEE Trans. Power Deliv., 2003, 18, pp. 12841292.
    17. 17)
      • 29. Holman, J.P.: ‘Heat transfer’ (McGraw-Hill, USA, 2007, 9th edn.).
    18. 18)
      • 23. Olivares-Galvan, J.C., Georgilakis, P.S., Campero-Littlewood, E., et al: ‘Core lamination selection for distribution transformers based on sensitivity analysis’, Electr. Eng., 2013, 95, pp. 3342.
    19. 19)
      • 2. 6100-3-6: ‘Limits – assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems’. 2008.
    20. 20)
      • 7. Slomovitz, D.: ‘Correction of power transformer no-load losses, measured under nonsinusoidal voltage waveforms’. IEE Proc. C Generation, Transmission and Distribution, 1989, pp. 4247.
    21. 21)
      • 27. Hirose, H., Sakumura, T.: ‘Foundation of mathematical deterioration models for the thermal stress’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, pp. 482485.
    22. 22)
      • 26. Vasconcellos, A.B., Carvalho, M.S.C.D., Carvalho, J.R.D., et al: ‘Energy efficiency and harmonic distortion in automation of air conditioning’. 2014 IEEE 16th Int. Conf. Harmonics and Quality of Power (ICHQP), Bucharest, 2014.
    23. 23)
      • 24. Winders, J.J.: ‘Power transformers: principles and applications’ (CRC Press, New York, 2002).
    24. 24)
      • 16. C57.123: ‘IEEE guide for transformer loss measurement’. 2010.
    25. 25)
      • 21. Dao, T., Phung, B.T.: ‘Study of voltage harmonic effect on temperature rise in distribution transformer’. 2016 IEEE Int. Conf. Power System Technology (POWERCON), Wollongong, Sydney, 2016.
    26. 26)
      • 15. C60076-2: ‘Power transformers – part 2: temperature rise for liquid-immersed transformers’. 2011.
    27. 27)
      • 9. Kefalas, T.D., Kladas, A.G.: ‘Harmonic impact on distribution transformer no-load loss’, IEEE Trans. Ind. Electron., 2010, 57, pp. 193200.
    28. 28)
      • 18. Olivares-Galvan, J.C., Ocon-Valdez, P.S.G.R.: ‘A review of transformer losses, electric power components and systems’. 2009, pp. 10461062.
    29. 29)
      • 5. Dao, T., Phung, B.T., Blackburn, T.: ‘Effects of voltage harmonics on distribution transformer losses’. 2015 IEEE PES Asia-Pacific Power and Energy Engineering Conf. (APPEEC), Brisbane, Australia, 2015, pp. 15.
    30. 30)
      • 17. Roshen, W.A.: ‘A practical, accurate and very general core loss model for nonsinusoidal waveforms’, IEEE Trans. Power Electron., 2007, 22, pp. 3040.
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2017.0498
Loading

Related content

content/journals/10.1049/iet-gtd.2017.0498
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading