Research on the correlation between the frequency-domain characteristics of corona current and A-weighted sound level of audible noise for UHV DC transmission line

Research on the correlation between the frequency-domain characteristics of corona current and A-weighted sound level of audible noise for UHV DC transmission line

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Audible noise is closely related to the frequency-domain characteristics of corona current. Based on the largest ultra-high-voltage (UHV) DC corona cage in the world and an actual UHV DC transmission line, a large amount of audible noise and corona current were measured simultaneously here. According to the statistical analysis of the experimental data, the correlation relationship between the frequency-domain characteristics of corona current and audible noise was obtained, and the causes of correlation rule were also analysed. Meanwhile, the correlation formula between the spectrum characteristics of corona current and A-weighted sound level of audible noise was discovered. The experimental results showed that the mathematical correlation formula discovered has good universality. The obtained results can provide theory and experimental foundation for deeply research on the essential connection between corona current and audible noise, which makes it possible to explore the causes of audible noise's change law from the perspective of ‘sound source’ and may provide a new method for audible noise estimation.

References

    1. 1)
      • 1. Mikropoulos, P.N., Zagkanas, V.N.: ‘The effect of stranded conductor geometry on DC corona in the coaxial cylindrical electrode arrangement in air’. Power Engineering Conf. (UPEC), 48th Int. Universities, 2013, pp. 15.
    2. 2)
      • 2. Li, M., Zong, R., Yang, D., et al: ‘The influence of wind on the audible noise of ultra HVDC transmission line in high altitude area’. 2010Asia-Pacific Int. Symp. on Electromagnetic Compatibility, Beijing, China, 2010, pp. 16681671.
    3. 3)
      • 3. Mikropoulos, P.N., Zagkanas, V.N., Koustoulidis, T.S.: ‘Experimental investigation of DC corona on stranded conductors under variable air density’. Universities Power Engineering Conf. (UPEC), 2012, pp. 16.
    4. 4)
      • 4. Bian, X., Wang, L., Liu, Y., et al: ‘High altitude effect on corona inception voltages of DC power transmission conductors based on the mobile corona cage’, IEEE Trans. Power Deliv., 2013, 28, (3), pp. 19711973.
    5. 5)
      • 5. Yang, P., Chen, S., He, J.: ‘Lightning impulse corona characteristic of 1000-kV UHVTransmission lines and its influences on lightning overvoltage analysis results’, IEEE Trans. Power Deliv., 2013, 28, (4), pp. 25182525.
    6. 6)
      • 6. Chen, L., Chen, F., Song, W., et al: ‘Corona phenomena for long-term operating conductor under different weather conditions’. Annual Report Conf. on Electrical Insulation and Dielectric Phenomena, 2013, pp. 156159.
    7. 7)
      • 7. Díaz, J., Ocampo, G., Chaves, S., et al: ‘Positive and negative point discharge corona currents: influence of thunderstorm-like wind velocities’. Int. Conf. on Lightning Protection (ICLP), Shanghai, China, 2014.
    8. 8)
      • 8. Wang, W., Yan1, B., Li, C., et al: ‘The effect of wind on corona current generated from DC conductor in corona cage’. 2008 Int. Conf. on High Voltage Engineering and Application, Chongqing, China, 9–13 November 2008, pp. 152153.
    9. 9)
      • 9. Nakano, Y., Sunaga, Y.: ‘Availability of corona cage for predicting audible noise generated from HVDC transmission line’, IEEE Trans. Power Deliv., 1989, 4, (2), pp. 14221431.
    10. 10)
      • 10. Chartier, V.L., Stearns, R.D.: ‘Measurement of audible noise from transmission lines’, IEEE Trans. Power Appar. Syst., 1981, 100, (3), pp. 14401452.
    11. 11)
      • 11. Sert, S.B., Kalenderli, O.: ‘Determination of source voltage from audible corona noise by neural networks’, IEEE Trans. Dielectr. Electr. Insul., 2009, 16, (1), pp. 224231.
    12. 12)
      • 12. Li, X., Cui, X., Tiebing Lu, , et al: ‘Time-domain characteristics of the audible noise generated by single corona source under positive voltage’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (2), pp. 870878.
    13. 13)
      • 13. Wang, W., An, B., Li, C., et al: ‘The effect of temperature and humidity on audible noise generated from UHV DC transmission lines’. Annual Report Conf. on Electrical Insulation Dielectric Phenomena, 2008, pp. 287289.
    14. 14)
      • 14. Ianna, F., Wilson, G.L., Bosack, D.J.: ‘Spectral characteristics of acoustic noise from metallic protrusions and water droplets in high electric fields’, IEEE Trans. Power Appar. Syst., 1974, 93, (6), pp. 17871796.
    15. 15)
      • 15. Yuanqing, L., Jian, G., Jiayu, L.: ‘Audible noise spectrum characteristics of UHVDC positive line using corona cage’, Gaodianya Jishu/High Voltage Engineering, 2013, 39, (6), pp. 13241330.
    16. 16)
      • 16. Li, X., Cui, X., Tiebing Lu, , et al: ‘Time-domain and frequency-domain characteristics of audible noise from single corona source’. 2014 Int. Conf. on Power System Technology (POWERCON 2014), Chengdu, October 20–22 2014, pp. 14101416.
    17. 17)
      • 17. Yuanqing, L., Jian, G., Jiayu, L.: ‘Audible noise spectrum characteristics of positive and negative wire in UHV corona cage’, Zhongguo Dianji Gongcheng Xuebao/Proc. Chin. Soc. Electr. Eng., 2014, 34, (18), pp. 29762982.
    18. 18)
      • 18. Niu, J., Shi, Y., Cai, M., et al: ‘Detection of sputum by interpreting the time-frequency distribution of respiratory sound signal using image processing techniques’, Bioinformatics, 2017, doi: 10.1093/bioinformatics/btx652.
    19. 19)
      • 19. Shi, Y., Wang, Y., Cai, M., et al: ‘Study on the aviation oxygen supply system based on a mechanical ventilation model Chin’, J. Aeronaut., 2017, doi: 10.1016/j.cja.2017.10.008.
    20. 20)
      • 20. Wen, T., Xiaowu, Z.: ‘Research review on audible noise control of transmission line’, High Volt. Appar., 2009, 45, (3), pp. 109112.
    21. 21)
      • 21. Bian, X.M., Chen, L., Yu, D., et al: ‘Influence of aged conductor surface conditions on AC corona-generated audible noise with a corona cage’, IEEE Trans. Dielectr. Electr. Insul., 2012, 19, (6), pp. 20372043.
    22. 22)
      • 22. Wang, W., Li, C., Liu, Y., et al: ‘Study of full scale UHV DC transmission line corona performance in corona cage’. Electrical Insulation, 2008. Conf. Record of the 2008 IEEE Int. Symp. on, 2008, pp. 6365.
    23. 23)
      • 23. Yi, Y., Zhang, C., Wang, L.: ‘Time-domain performance of audible noise for positive DC corona: numerical simulation and measurements’, IEEE Trans. Dielectr. Electr. Insul., 2016, 23, (6), pp. 32753282.
    24. 24)
      • 24. Liu, Y., Zhou, L., Liu, Y., et al: ‘Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line’, Phys. Plasmas, 2017, 24, (11), doi: 10.1063/1.4999228.
    25. 25)
      • 25. Li, X., Cui, X., Lu, T., et al: ‘The correlation between audible noise and corona current in time domain caused by single positive corona source on the conductor’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (2), pp. 13141320.
    26. 26)
      • 26. Liu, Y., Yuan, H., Qinghua, Y., et al: ‘Design of the corona current measurement sensor with wide bandwidth under DC ultra high-voltage environment’, Meas. Sci. Technol., 2011, 22, (12), pp. 19.
    27. 27)
      • 27. Liu, Y.Y., Zhou, L.J., Liu, Y.Q., et al: ‘Analysis on the spectrum characteristic of corona current and its relationship with radio interference on UHVDC transmission line’, IEEE Trans. Dielectr. Electr. Insul, 2016, 23, (6), pp. 33363345.
    28. 28)
      • 28. Liu, Y.Y., Zhou, L.J., Liu, Y.Q., et al: ‘Method for calculating corona inception voltage of ultra-high-voltage direct current transmission lines with frequency-domain characteristics of corona current’, IET Gener. Transm. Distrib., 2017, 11, (15), pp. 37833790.
    29. 29)
      • 29. Rui, L.: ‘Research on DC positive corona discharge characteristics of conductors and its affecting factors’. PhD thesis, Chongqin University, 2009.
    30. 30)
      • 30. Whitehead, J.B.: ‘High-voltage corona in international critical tables’ (McGraw-Hill, New York, 1929).
    31. 31)
      • 31. Stockmeyer, W.: ‘Koronaverluste bei hoher Gleichspannung’, Wiss. Verofl. Siemens, 1934, 13, (2), pp. 2734.
    32. 32)
      • 32. Youwei, L., Jihong, L., Bin, L.: ‘Influence of air density and humidity on corona performance of Dc conductor’, Power Syst. Technol., 1990, 4, (45), pp. 4650.