Recloser time–current–voltage characteristic for fuse saving in distribution networks with DG

Recloser time–current–voltage characteristic for fuse saving in distribution networks with DG

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Utilities apply a fuse-saving strategy during auto-reclosing on transient faults. Integration of distribution generation (DG) into distribution networks (DNs) challenges this strategy as the fault current contribution from the DG may lead to the loss of recloser–fuse coordination. This study proposes a relaying scheme to be applied on microprocessor-based reclosers for fuse saving under transient fault conditions. A relay operating characteristic is defined which utilises voltage and current magnitudes at the recloser location. The voltage term in the relay characteristic compensates for the reclosing delay resulting from the DG fault contribution. The main features of the relaying scheme are use of local measurements, i.e. no communication link is required, and its independence of number and location of DG. The proposed relaying scheme is validated by simulation study on a practical 20 kV Iranian DN. It is shown that the new scheme maintains proper recloser–fuse coordination for different fault conditions and DG configurations. Moreover, the maximum DG penetration in different locations is obtained whilst the recloser–fuse coordination is upheld. It is shown in a comparative study that the proposed relaying scheme can maintain the coordination for higher DG penetrations than a recent adaptive method reported in the literature.

References

    1. 1)
      • 1. Barker, P.P., Mello, R.W.D.: ‘Determining the impact of distributed generation on power systems. I. Radial distribution systems’. Proc. IEEE Power Engineering Society Summer Meeting 2000, vol. 3, pp. 16451656.
    2. 2)
    3. 3)
    4. 4)
    5. 5)
    6. 6)
    7. 7)
      • 7. Zeineldin, H.H., El-Saadany, E.F.: ‘Fault current limiters to mitigate recloser–fuse miscoordination with distributed generation’. Proc. Managing the Change, Tenth IET Int. Conf. Developments in Power System Protection (DPSP), 2010, pp. 14.
    8. 8)
    9. 9)
    10. 10)
    11. 11)
    12. 12)
      • 12. Brahma, S.M., Girgis, A.A.: ‘Microprocessor-based reclosing to coordinate fuse and recloser in a system with high penetration of distributed generation’. Proc. IEEE Power Engineering Society, Winter Meeting, 2002, vol. 1, pp. 453458.
    13. 13)
      • 13. Zamani, A., Sidhu, T., Yazdani, A.: ‘A strategy for protection coordination in radial distribution networks with distributed generators’. Proc. IEEE Power and Energy Society, General Meeting, 2010, pp. 18.
    14. 14)
    15. 15)
    16. 16)
      • 16. Blackburn, J.L., Domin, T.J.: ‘Protective relaying: principles and applications’ (Taylor & Francis, USA, 1987, 2014, 4th edn.).
    17. 17)
      • 17. IEEE Std C37.112-1996: ‘IEEE standard inverse-time characteristic equations for overcurrent relays’, 1997.
    18. 18)
    19. 19)
    20. 20)
    21. 21)
    22. 22)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2016.0979
Loading

Related content

content/journals/10.1049/iet-gtd.2016.0979
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address