http://iet.metastore.ingenta.com
1887

Study on the hybrid ion-flow field of HVDC and HVAC transmission lines by the nodal discontinuous Galerkin time-domain method

Study on the hybrid ion-flow field of HVDC and HVAC transmission lines by the nodal discontinuous Galerkin time-domain method

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The high-voltage direct current (HVDC) and HV alternating current (HVAC) hybrid transmission lines in the same corridor is an effective way to enhance the power transmission capacity of the corridor and save land resource. The transmission lines parameters such as the corridor width, the height of transmission lines, and electromagnetic environment can be analysed and optimised by the calculation of the hybrid ion-flow field. In this study, nodal discontinuous Galerkin time-domain method is for the first time applied to the calculation of the hybrid ion-flow field. Furthermore, corona interactions between the HVDC and HVAC lines are considered in the process of numerical solution. Compared with measured results and previous methods, the proposed approach is verified to be able to obtain wiggle-free numerical solution with significantly reducing the computational burden, and meanwhile, the calculation precision is increased greatly. The ground-level electric field and ion current density of the hybrid lines in time domain are analysed, and then the time-domain characteristic is explored. Finally, the ion-flow fields of the hybrid ±800 kV DC/500 kV AC transmission lines in parallel and on the same tower have been made a comparative analysis and optimisation, which provide theoretical basis for real hybrid towers design.

References

    1. 1)
    2. 2)
    3. 3)
    4. 4)
    5. 5)
    6. 6)
      • 6. Zhao, T., Illan, J., Cohol, J.M., et al: ‘Design, construction and utilization of a new reduced-scale model for the study of hybrid (AC and DC) line corona’. Proc. IEEE Power Engineering Society, Transmission and Distribution Conf., Chicago, IL, 1994, pp. 239245.
    7. 7)
    8. 8)
    9. 9)
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
      • 15. Popkov, V.I.: ‘On the theory of unipolar DC corona’, Elektrichestvo, 1949, 1, pp. 3348.
    16. 16)
    17. 17)
    18. 18)
      • 18. Maruvada, P.S.: ‘Corona performance of high-voltage transmission lines’, ser. Electron. Electr. Eng. Res. Studies: High-Voltage Power transmission series (Research Studies Press, UK, 2000).
    19. 19)
    20. 20)
    21. 21)
      • 21. Hesthaven, J.S., Warburton, T.: ‘Nodal discontinuous Galerkin methods: algorithms, analysis, and applications’ (Springer, Berlin, 2008).
    22. 22)
    23. 23)
    24. 24)
    25. 25)
      • 25. Carpenter, M.H., Kennedy, C.A.: ‘Fourth-order 2N-storage Runge–Kutta schemes’. NASA Report, TM 109112, NASA Langley Research Center, 1994.
    26. 26)
    27. 27)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2016.0843
Loading

Related content

content/journals/10.1049/iet-gtd.2016.0843
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address