Synchrophasor-based backup distance protection of multi-terminal transmission lines

Synchrophasor-based backup distance protection of multi-terminal transmission lines

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

The distance protection of multi-terminal transmission lines need to be redesigned due to possible changes in the backup protection emanating from probable infeed currents produced from tapped transmission lines. Furthermore, high-resistance fault is another factor that relay become under-reach and cannot correctly identify the fault. In this study, an algorithm is presented based on synchrophasors. In this method, voltage and current signals of buses will be sent to system protection centre (SPC) and in SPC an algorithm based on active power calculation in buses is provided that is able to eliminate the effects of both mentioned factors. In this method, measurement or relay in tapped transmission line location are not required. The study includes analytical analysis and modelling and in modelling results a variety of faults with different fault resistances is considered. Two power systems including teed-feeder system and IEEE 14-bus power system are considered. The results show that in both power systems, and different types of faults, backup distance protection is improved. Simulations are conducted by Electro-Magnetic Transient Program works.

References

    1. 1)
      • 1. Horowitz, S.H., Phadke, A.G.: ‘Power system relaying’ (John Wiley & Sons Ltd, Chichester, England, 2008).
    2. 2)
    3. 3)
    4. 4)
    5. 5)
    6. 6)
    7. 7)
    8. 8)
    9. 9)
    10. 10)
    11. 11)
    12. 12)
      • 12. Ghorbani, A., Soleymani, S., Mozafari, B.: ‘A PMU-based LOE protection of synchronous generator in the presence of GIPFC’, IEEE Trans. Power Deliv., 2016, 31, (2), pp. 551–558.
    13. 13)
    14. 14)
    15. 15)
    16. 16)
    17. 17)
    18. 18)
    19. 19)
    20. 20)
    21. 21)
    22. 22)
    23. 23)
    24. 24)
      • 24. C37.118: ‘IEEE standard for synchrophasor measurements for power systems’, 2005.
    25. 25)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2016.0223
Loading

Related content

content/journals/10.1049/iet-gtd.2016.0223
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address