Islanding detection method adopting single-phase-operating circuit breaker

Islanding detection method adopting single-phase-operating circuit breaker

For access to this article, please select a purchase option:

Buy article PDF
$19.95
(plus tax if applicable)
Buy Knowledge Pack
10 articles for $120.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

This study proposes a novel islanding detection method adopting single-phase-operating circuit breaker (CB). The method aims to utilise the operation of CB to generate specific electric information to the distributed generator (DG), instead of using a dedicated signal generator at the substation. When islanding forms, the CB opens three-phase circuits asymmetrically to indicate the islanding, which causes asymmetric operation of the local system within a predefined short time. During this period, negative-sequence voltage with certain duration is obtained at DG side. Furthermore, the varying characteristics of three-phase voltages from close status to open status of CB are the same, which can be utilised to distinguish the formation of islanding from system disturbances. The method is tested based on a typical medium-voltage distribution network with synchronous DG interconnection. Test results show the effectiveness of the proposed method under both islanding formation and system disturbance scenarios.

References

    1. 1)
      • 1. ‘IEEE Std. 1547.2-2008: ‘IEEE Application Guide for IEEE Std. 1547, IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems’, 2009.
    2. 2)
      • 2. ‘IEEE Std. 1547-2003: ‘IEEE Standard for Interconnecting Distributed Resources with Electric Power Systems’, 2003.
    3. 3)
    4. 4)
    5. 5)
      • 5. Xu, W., Mauch, K., Martel, S.: ‘An assessment of DG islanding detection methods and issues for Canada’. CANMET Energy Technology Centre-Varennes, Natural Resources Canada, 2004, pp. 1223.
    6. 6)
    7. 7)
    8. 8)
    9. 9)
    10. 10)
    11. 11)
    12. 12)
    13. 13)
    14. 14)
    15. 15)
    16. 16)
    17. 17)
      • 17. ABB Inc.: ‘WPO-123-1 MV outdoor products for smart grid demands’. Available at http://www09.abb.com/global/scot/scot299.nsf/veritydisplay/f009b0967b248d5a852578ef004f156b/$file/WPO-123-1.pdf., accessed January 2015.
    18. 18)
      • 18. ABB Inc.: ‘GridShield: 15/27/38 kV three-phase vacuum recloser’. Available at http://www.new.abb.com/medium-voltage/apparatus/reclosers., accessed January 2015.
    19. 19)
      • 19. Cheney, R.M., Thorne, J.T., Hataway, G.: ‘Distribution single-phase tripping and reclosing: overcoming obstacles with programmable recloser controls’. Power Systems Conf., Clemson, USA, March 2009, pp. 110.
    20. 20)
      • 20. State Grid of China: ‘Typical distribution network power supply modes’, 2014.
    21. 21)
      • 21. GB/T 15543-2008: ‘PRC National Standard: Quality of electric energy supply – admissible three-phase voltage unbalance factor’, 2008.
    22. 22)
      • 22. GB 12325-90: ‘PRC National Standard: Quality of electric energy supply – admissible deviation of supply voltage’, 2005.
    23. 23)
    24. 24)
    25. 25)
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2015.0815
Loading

Related content

content/journals/10.1049/iet-gtd.2015.0815
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address