Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

Analysis of accelerated ageing of non-ceramic insulation equipments

Analysis of accelerated ageing of non-ceramic insulation equipments

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

Ageing of non-ceramic insulation can conduct into failures of the power system, where usually pollution plays an important role in the degradation process. These failures cannot be evaluated by applying IEC 61109 ageing tests, because such tests are considered as screening tests and up to now these tests are quite questionable. Therefore research of new test methods and diagnostic tools are needed to predict long-term performance of non-ceramic insulators. A non-standard method for insulation ageing is modified and used in this work to evaluate non-ceramic components of breakers, bushings and surge arresters. Different diagnostic tests are proposed to analyse the evolution in the degradation process of these apparatus. The results showed that the applied methodology and the proposed tests may evaluate in a more realistic way the performance of new non-ceramic insulating material used in electrical equipment.

References

    1. 1)
      • Perrot, F.: `Multifactor pollution testing to asses the long term performance of composite surge arresters and insulators', Proc. Int. Conf. ISH, August 1999, London, UK, p. 34–37.
    2. 2)
      • M.T. Gençoğlu . The comparison of ceramic and non-ceramic insulators. e-J. New World Sci. Acad., Nat. Appl. Sci. , 4 , 274 - 294
    3. 3)
      • Qaddoumi, N., El-Hag, A.H., Hosani, M.A., Mansouri, I.A., Ghufli, H.A.: `Detecting damages in outdoor non-ceramic insulators using near field microwave non-destructive testing', IEEE EIC, May 2009, Montreal, QC, Canada, p. 64–66.
    4. 4)
    5. 5)
    6. 6)
    7. 7)
      • Gorur, R.S., Berstein, B.S., Champion, T., Orbeck, T.: `Evaluation of polimeric materials for HV outdoor insulation', CIGRE Int. Conf. Large High Voltage Electric Systems, 1994, p. 1–8, Publication 15–107.
    8. 8)
    9. 9)
      • R.S. Gorur . (2010) Six utilities share their perspectives on insulators.
    10. 10)
    11. 11)
    12. 12)
    13. 13)
      • Angelini, J.M.G., Costa, G.E., Formiga, A.M., Mendonca, P.L., Shinohara, A.H., Ferreira, T.V.: `Deterioration of polymeric insulators using exclusive agents', CIRED Int. Conf. Electricity Distribution, June 2009, Prague.
    14. 14)
      • Ansorge, S., Schmuck, F., Aitken, S., Papailiou, K.O.: `Improved performance of silicone rubbers for the use in composite insulators', CIGRE, August 2010, Paris, France, Session 4, D1–105.
    15. 15)
    16. 16)
    17. 17)
    18. 18)
      • Linders, M., Elstein, S., Linders, P., Topaz, J.M., Phillips, A.J.: `Daylight corona discharge imager', Proc. Int. Conf. ISH, August 1999, London, UK, p. 349–352.
    19. 19)
    20. 20)
      • Saldivar-Guerrero, R., López-González, F., Hernández-Corona, R., Paniagua-García, R.: `Physical and chemical characterization of polymer housed surge arresters tested under accelerated weathering', Proc. Int. Symp. Electrical Insulating, September 2008, Yokkaichi, Mie, Japan, p. 291–294.
    21. 21)
    22. 22)
    23. 23)
      • R.S. Gorur , E.A. Cherney , J.T. Burnham . (1999) Outdoor insulators.
    24. 24)
    25. 25)
    26. 26)
    27. 27)
    28. 28)
      • K.S. Sidhu . Transmission line insulation: composites. (Reference book, electrical India , 12
    29. 29)
      • Bo, H., Jun, W., Haiyun, J., Naikui, G., Zongren, P.: `Aging characters analysis of composite insulators', Int. Conf. HVEA, November 2008, Chongqing, China, p. 415–419.
    30. 30)
      • A.J. Carreira . Condition detection of non-ceramic insulators for live line work at electric utilities. Insulator News and Market Report (INMR) , 2 , 26 - 35
    31. 31)
    32. 32)
      • D. Birtwhistle , G. Cash , G.A. George , D. Hinde . New techniques for life cycle management of polymeric insulators in high voltage electricity networks. Aust. J. Mech. Eng. , 2 , 139 - 149
    33. 33)
    34. 34)
      • Villancourt, G.H., Hamel, M., Frate, J.: `Experience with two faulty composite insulators detection methods in Hydro-Quebec', Proc. Int. Conf. ISH, August 1997, Montreal, Canada, p. 25–29.
    35. 35)
    36. 36)
      • W.C. Godoi , K. De Geus , V. Swinka-Filho , R.R. Da Silva . Volume and surface measurements of flaws in polymeric insulators using X-ray computed termography. Br. Inst. Non-Destr. Test., Non-Destr. Test. Cond. Monit. , 10 , 554 - 559
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2011.0078
Loading

Related content

content/journals/10.1049/iet-gtd.2011.0078
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address