Your browser does not support JavaScript!
http://iet.metastore.ingenta.com
1887

New approach to adaptive single pole auto-reclosing of power transmission lines

New approach to adaptive single pole auto-reclosing of power transmission lines

For access to this article, please select a purchase option:

Buy article PDF
£12.50
(plus tax if applicable)
Buy Knowledge Pack
10 articles for £75.00
(plus taxes if applicable)

IET members benefit from discounts to all IET publications and free access to E&T Magazine. If you are an IET member, log in to your account and the discounts will automatically be applied.

Learn more about IET membership 

Recommend Title Publication to library

You must fill out fields marked with: *

Librarian details
Name:*
Email:*
Your details
Name:*
Email:*
Department:*
Why are you recommending this title?
Select reason:
 
 
 
 
 
IET Generation, Transmission & Distribution — Recommend this title to your library

Thank you

Your recommendation has been sent to your librarian.

In this study, a novel digital algorithm is introduced for recognition of arcing (transient) faults and determination of dead time for adaptive auto-reclosing. The algorithm distinguishes between arcing and permanent faults by using the zero sequence voltage measured at the relaying point. If the fault is recognised as an arcing fault, then the third harmonic of the zero sequence voltage is used to evaluate the extinction time of secondary arc and to initiate reclosing signal. The proposed algorithm uses an adaptive threshold level and therefore no significant adjustment is needed for different transmission systems. Moreover, its performance is independent to fault location, line parameters and the system pre-fault operating conditions. The algorithm has been successfully tested for various faults and operating conditions on a 400 kV overhead line using the electro-magnetic transient program (EMTP). The test results have demonstrated validity of the algorithm in determining the secondary arc extinction time and blocking unsuccessful automatic reclosing during permanent faults.

References

    1. 1)
      • Lin, X., Liu, P.: `Method of distinguishing between instant and permanent faults of transmission lines based on fuzzy decision', IEEE Catalog No. 98EX137, 1998, p. 455–460.
    2. 2)
      • A.T. Johns , R.K. Aggarwal , Y. Song . Improved technique for modelling fault arcs on faulted EHV transmission systems. IEE Proc. Gener. Transm. Distrib. , 2 , 148 - 154
    3. 3)
      • G. Yaozhang , S. Fanghai , X. Yuan . Prediction method for preventing single-phase reclosing on permanent faults. IEEE Trans. Power Deliv. , 1 , 114 - 121
    4. 4)
      • Bo, Z.Q., Aggarwal, R.K., Johns, A.T.: `A novel technique to distinguish between transient and permanent fault based on detection of current transients', Proc. Fourth Int. Conf. Advances in Power System Control and Management, November 1997, p. 217–220.
    5. 5)
      • N.I. Elkalashy , H.A. Darwish , A.M.I. Taalab , M.A. Izzularab . An adaptive single pole auto-reclosure based on zero sequence power. Electr. Power Syst. Res. , 438 - 446
    6. 6)
      • Jamali, S., Shateri, H.: `Robustness of distance relay with Mho characteristic against fault resistance', Proc. Int. Conf. Power System Technology, POWERCON 2004, November 2004.
    7. 7)
      • I.K. Yu , Y.H. Song . Wavelet transform and neural network approach to developing adaptive single-pole auto-reclosing schemes for EHV transmission systems. IEEE Power Eng. Rev. , 11 , 62 - 64
    8. 8)
      • R.K. Aggarwal , A.T. Johns , R.W. Dunn , D.S. Fitton . Neural network based adaptive single-pole auto-reclosure technique for EHV transmission system. IEE Proc. Gener. Transm. Distrib. , 2 , 155 - 160
    9. 9)
      • L. Prikler , M. Kizilcay , G. Ban , P. Handl . Modeling secondary arc based on identification of arc parameters from staged fault test records. Electr. Power Energy Syst. , 581 - 589
    10. 10)
      • Z.M. Radojevuc , J.R. Shin . New digital algorithm for adaptive reclosing based on the calculation of the faulted phase voltage total harmonic distortion factor. IEEE Trans. Power Deliv. , 1 , 37 - 41
    11. 11)
      • C.E.J. Bowler , P.G. Brown , D.N. Walker . Evaluation of the effect of power circuit breaker reclosing practices on turbine-generator shaft. IEEE Trans. Power Appar. Syst. , 1764 - 1779
    12. 12)
      • H.W. Dommel . (1997) EMPT reference manual.
    13. 13)
      • M. Kizilcay , T. Pniok . Digital simulation of fault arcs in power systems. Eur. Trans. Electr. Power Syst. , 3 , 55 - 59
    14. 14)
      • S.P. Ahn , C.H. Kim , R.K. Aggarwal , A.T. Johns . An alternative approach to adaptive single pole auto-reclosing in high voltage transmission systems based on variable dead time control. IEEE Trans. Power Deliv. , 4 , 676 - 686
http://iet.metastore.ingenta.com/content/journals/10.1049/iet-gtd.2009.0058
Loading

Related content

content/journals/10.1049/iet-gtd.2009.0058
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading
This is a required field
Please enter a valid email address