access icon openaccess Dynamic formation mechanism of water droplet and induced surface discharges on silicone rubber composites

  • HTML
    62.658203125Kb
  • XML
    58.2841796875Kb
  • PDF
    5.032526016235352MB
Loading full text...

Full text loading...

/deliver/fulltext/hve/4/1/HVE.2018.5082.html;jsessionid=1jefc102l7ok8.x-iet-live-01?itemId=%2fcontent%2fjournals%2f10.1049%2fhve.2018.5082&mimeType=html&fmt=ahah

References

    1. 1)
      • 1. Knauel, J., Wagner, A., Puffe, R.: ‘Behavior of water droplets on polymeric insulation surfaces under hybrid field stress’. IEEE Conf. Electrical Insulation Dielectrics Phenomena, Des Moines, IA, USA, 2014, pp. 243246.
    2. 2)
      • 2. Ndoumbe, J., Beroual, A., Imano, A. M.: ‘Simulation and analysis of coalescence of water droplets on composite insulating surface under DC electric field’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (5), pp. 26692675.
    3. 3)
      • 3. El-Kishky, H., Gorur, R.S.: ‘Electric field computation on an insulating surface with discrete water droplets’, IEEE Trans. Dielectr. Electr. Insul., 1996, 3, (3), pp. 450456.
    4. 4)
      • 4. Souza, A.L., Lopes, I.J.S.: ‘Experimental investigation of corona onset in contaminated polymer surfaces’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (2), pp. 13211331.
    5. 5)
      • 5. Du, B.X., Ma, Z.L., Cheng, X.X.: ‘Hydrophobicity evaluation of silicone rubber insulator using PD-induced electromagnetic wave’, IEEE Trans. Dielectr. Electr. Insul., 2012, 19, (3), pp. 10601067.
    6. 6)
      • 6. Bouhaouche, M., Mekhaldi, A., Teguar, M.: ‘Improvement of electric field distribution by integrating composite insulators in a 400 kV AC double circuit line in Algeria’, IEEE Trans. Dielectr. Electr. Insul., 2017, 24, (6), pp. 35493558.
    7. 7)
      • 7. Lopes, I.J.S., Jayaram, S.H., Cherney, E.A.: ‘A study of partial discharges from water droplets on a silicone rubber insulating surface’, IEEE Trans. Dielectr. Electr. Insul., 2001, 8, (2), pp. 262268.
    8. 8)
      • 8. Kin, R., Kurimoto, M., Murakami, Y.: ‘Dynamic behavior of water droplet on silicone rubber surface in dynamic drop test’. IEEE Int. Conf. Electrical Insulating Materials, Kyoto, Japan, 2014, pp. 249252.
    9. 9)
      • 9. Aouabed, F., Bayadi, A., Rahmani, A.E.: ‘Finite element modelling of electric field and voltage distribution on a silicone insulating surface covered with water droplets’, IEEE Trans. Dielectr. Electr. Insul., 2018, 25, (2), pp. 413420.
    10. 10)
      • 10. Fortner, N., Shapiro, B.: ‘Equilibrium and dynamic behavior of micro flows under electrically induced surface tension actuation forces’. IEEE Conf. MEMS Nano and Smart Systems, Banff, Alberta, Canada, 2003, pp. 197202.
    11. 11)
      • 11. Wang, J., Wen, X., Lei, L.: ‘Study of discharge process and characteristics of discrete water droplets on the RTV hydrophobic surface in the non-uniform electric field’. IEEE Conf. Power Systems Technology, Chongqing, China, 2006, pp. 16.
    12. 12)
      • 12. Beroual, A.: ‘Dynamics of water droplets immersed in dielectric liquids submitted to electric stress’, IEEE Trans. Dielectr. Electr. Insul., 2015, 22, (1), pp. 359365.
    13. 13)
      • 13. Nazemi, M.H., Hinrichsen, V.: ‘Experimental investigations on water droplet oscillation and partial discharge inception voltage on polymeric insulating surfaces under the influence of AC electric field stress’, IEEE Trans. Dielectr. Electr. Insul., 2013, 20, (2), pp. 443453.
    14. 14)
      • 14. Li, J., Wei, Y., Huang, Z.: ‘Investigation of the electric field driven self-propelled motion of water droplets on a super-hydrophobic surface’, IEEE Trans. Dielectr. Electr. Insul., 2016, 23, (5), pp. 30073015.
    15. 15)
      • 15. Sarathi, R., Mishra, P., Gautam, R.: ‘Understanding the influence of water droplet initiated discharges on damage caused to corona-aged silicone rubber’, IEEE Trans. Dielectr. Electr. Insul., 2017, 24, (4), pp. 24212431.
    16. 16)
      • 16. Mizuno, Y., Nagata, M., Naito, K.: ‘Water droplet behavior and discharge activity on silicone rubber surface energized by AC voltage’. IEEE Conf. Electrical Insulation Dielectrics Phenomena, Waterloo, Ontario, Canada, 2001, pp. 624627.
    17. 17)
      • 17. Zhang, C., Wang, L., Guan, Z.: ‘Investigation of DC discharge behavior of polluted porcelain post insulator in artificial rain’, IEEE Trans. Dielectr. Electr. Insul., 2016, 23, (1), pp. 331338.
    18. 18)
      • 18. Sarang, B., Lakdawala, V., Basappa, P.: ‘Electric field calculations on a high voltage insulator under wet conditions’. IEEE Conf. Dielectrics Electrical Insulation, Montreal, Quebec, Canada, 2009, pp. 8690.
    19. 19)
      • 19. Sarathi, R., Mishra, P., Gautam, R.: ‘Understanding the influence of water droplet initiated discharges on damage caused to corona-aged silicone rubber’, IEEE Trans. Dielectr. Electr. Insul., 2017, 24, (4), pp. 24212431.
    20. 20)
      • 20. Yang, X., Song, B., Bin, X., et al: ‘Spreading behaviors of silicone droplet impact on flat solid surface: experiments and VOF simulations’. IEEE Conf. Electronic Packaging Technology, Changsha, China, 2015, pp. 14.
    21. 21)
      • 21. Tilford, T., Stoyanov, S., Tourloukis, G.: ‘Numerical analysis of droplet deposition in inkjet printed electronics assembly’. IEEE Conf. Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems, Montpellier, France, 2016, pp. 17.
    22. 22)
      • 22. Chatterjee, S., Nazemi, M. H.: ‘Influence of viscosity and conductivity of water droplets on partial discharge inception voltages of polymeric insulating surfaces’. IEEE Conf. Energy, Power and Environment: Towards Sustainable Growth, Shillong, India, 2016, pp. 14.
    23. 23)
      • 23. Luo, X., Zhu, D., Shi, L.: ‘Investigation of calculating solid surface tension based on contact angle method’, Sci. Technol. Eng., 2007, 7, (19), pp. 49975004.
    24. 24)
      • 24. Lopes, I.J.S., Jayaram, S.H., Cherney, E.A.: ‘A study of partial discharges from water droplets on a silicone rubber insulating surface’, IEEE Trans. Dielectr. Electr. Insul., 2001, 8, (2), pp. 262268.
    25. 25)
      • 25. Phillips, A.J., Childs, D.J., Schneider, H.M.: ‘Water drop corona effects on full-scale 500 kV non-ceramic insulators’, IEEE Trans. Power Deliv., 1999, 14, (1), pp. 258265.