A 4 ps high-sensitivity optical sampling scheme based on a fast GaAs saturable absorber created by heavy-ion irradiation is demonstrated. The intensity-invariant saturable absorber permits high-level inhomogeneous pumping leading to a high open/close ratio of 1000 and to a system sensitivity limited by the level of saturable absorber spontaneous emission.