© The Institution of Electrical Engineers
A fluxgate sensor with amorphous race-track (oval) core is described. The sensor measures DC magnetic field and magnetic field gradient simultaneously. The noise RMS values are 10 pT and 10 pT/cm, respectively, both in the 20 MHz–10 Hz frequency range.
References
-
-
1)
-
O.V. Nielsen ,
J.R. Petersen ,
A. Fernandez ,
B. Hernando ,
P. Spisak ,
F. Primdahl ,
N. Moser
.
Analysis of a fluxgate magnetometer based on metallic glass sensor.
Meas. Sci. Technol.
,
435 -
440
-
2)
-
Ripka, P., Sedlacek, M., Janasek, V.: `Ambulatory noise analysis system', Papers S 15-4, Proc. Imeko TC-4 Symposium, 12–13 May 1993, Brussels, Belgium.
-
3)
-
P. Ripka
.
Review of fluxgate sensors.
Sens. & Actuators A
,
129 -
141
-
4)
-
P. Ripka ,
P. Jires ,
M. Machacek
.
Fluxgate sensor with increased homogeneity.
IEEE Trans.
,
2041 -
2048
-
5)
-
M.D. Mermelstein ,
A. Dandridge
.
Metallic glass ribbon probe for the measurement of the magnetic field, first and second order field gradients.
Electron. Lett.
,
501 -
503
-
6)
-
R.Ja. Berkman
.
O novom variante magnitomodulacionnovo datschika dlja izmerenija gradientov naprjazhennosti magnitnych polej (About a new type of magnetomodulation transducers for measurement of the magnetic field gradient).
Avtom. Kontrol i Izmer. Tech.
,
157 -
162
http://iet.metastore.ingenta.com/content/journals/10.1049/el_19930797
Related content
content/journals/10.1049/el_19930797
pub_keyword,iet_inspecKeyword,pub_concept
6