Radio frequency (RF) heating is a serious risk for a patient with an elongated implant during MRI scan. The conventional dosimeter of specific absorption rate (SAR) and the recently proposed B 1+rms may not accurately indicate the implant heating. The local B 1 field around the tip of a lead and its relationship with the RF heating were studied by numerical simulations. It was found that regardless of the route of the lead, the angle or position of placement, there was a strong linear correlation between the averaged square of local B 1 field and the rise in temperature. The evaluation range had an effect on the linearity. Generally, the local B 1 field performed better as a dosimeter of RF heating than SAR or B 1+rms at the isocentre.
References
-
-
1)
-
5. Milne, A.A.: ‘Current issues in MRI safety’, in Anthony, B. (Ed.): ‘Advances in medical physics’ (Medical Physics Publishing, Madison, WI, USA, 2012), pp. 195–203.
-
2)
-
2. Rossi, S., Hallett, M., Rossini, P.: ‘Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research’, Clin. Neurophysiol., 2009, 120, (12), pp. 2008–2039, (doi: 10.1016/j.clinph.2009.08.016).
-
3)
-
3. Faulkner, W.: ‘New MRI safety labels & devices’, Signals, 2016, 5, (1), available at https://www.ismrm.org/smrt/E-Signals/2016FEBRUARY/eSig_5_1_hot_2.htm.
-
4)
-
7. : ‘Standard test method for measurement of radio frequency induced heating on or near passive implants during magnetic resonance imaging’, 2011.
-
5)
-
6. Ding, J., Jiang, C., Zhang, F.: ‘Role of MRI coils in radio frequency heating of implantable medical devices’, Electron. Lett., 2018, 54, (11), pp. 682–684, (doi: 10.1049/el.2018.0551).
-
6)
-
4. Shulman, R.M., Hunt, B.: ‘Cardiac implanted electronic devices and MRI safety in 2018 – the state of play’, Eur. Radiol., 2018, 2, (1), pp. 28–30, (doi: 10.1186/s41747-018-0059-0).
-
7)
-
2. Baker, K.B., Tkach, J.A., Nyenhuis, J.A.: ‘Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating’, J. Magn. Reson. Imag., 2004, 20, (2), pp. 315–320, (doi: 10.1002/jmri.20103).
-
8)
-
8. Jiang, C., Hao, H., Li, L.: ‘Artifact properties of carbon nanotube yarn electrode in magnetic resonance imaging’, J. Neural. Eng., 2013, 10, (2), p. 026013, (doi: 10.1088/1741-2560/10/2/026013).
http://iet.metastore.ingenta.com/content/journals/10.1049/el.2018.6857
Related content
content/journals/10.1049/el.2018.6857
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Correspondence
This article has following corresponding article(s):
Beside the point