access icon free Non-invasive piezoelectric detection of heartbeat rate and blood pressure

A non-invasive piezoelectric-based sheet sensor is utilised for the deliberate measurement of heartbeat rate and blood pressure. It may consist of a single sheet to capture various temporal signals or it can be formed as an array of small piezoelectric sensors to capture the temporal and spatial cardiac signals over the chest to give an added spatial granularity on top of the localised temporal signal. The mechanical activity of the heart will cause the piezoelectric sheet to deform, and thus produce a voltage signal. To count the heartbeat rate, a mechanical model has been developed using the corresponding electric waveform; a compression ratio is defined due to the delay as a result of the physical coupling mechanism. Validation of the obtained results has been performed using conventional techniques and apparatus. The quantitative assessment shows low errors when compared with other conventional meters.

Inspec keywords: cardiology; electric sensing devices; blood pressure measurement; bioelectric potentials; piezoelectric devices

Other keywords: voltage signal; heartbeat rate measurement; compression ratio; blood pressure measurement; physical coupling mechanism; heart mechanical activity; piezoelectric-based sheet sensor; temporal cardiac signals; noninvasive piezoelectric detection; chest; localised temporal signal; spatial cardiac signals

Subjects: Sensing devices and transducers; Electrical activity in neurophysiological processes; Pressure and vacuum measurement; Haemodynamics, pneumodynamics; Bioelectric signals; Electrodiagnostics and other electrical measurement techniques; Piezoelectric devices

References

    1. 1)
      • 11. PI ceramic: ‘P-876 DuraAct patch transducer’, Available at http//www.piceramic.com, accessed December 2014.
    2. 2)
      • 8. ECG: ‘B. ECG challenge response’, Circulation, 2014, 129, (922), doi: 10.1161/CIRCULATIONAHA.114.008852.
    3. 3)
    4. 4)
    5. 5)
      • 3. Pierre, A., Kreitmann, B., Habib, G.: ‘Home blood pressure monitoring in heart transplant recipients: comparison with ambulatory blood pressure monitoring’, Transplantation, 2014, 97, (3), pp. 363367, doi: 10.1097/01.TP.0000435704.55805.f9.
    6. 6)
      • 6. Schmidt, M., Sow, D., Crimmins, M., Albers, D., Agarwal, S., Claassen, J., Connolly, E., Elkind, M., Hripcsak, G., Mayer, S.: ‘Heart rate variability for preclinical detection of secondary complications after subarachnoid hemorrhage’, J. Neural Care, 2014, 20, (3), pp. 382389, doi: 10.1007/s12028-014-9966-y.
    7. 7)
    8. 8)
      • 2. Mcmanus, D., Riistema, J., Saczynski, J., Kuniyoshi, F., Rock, J., Meyer, T., Teuling, N., Goldberg, R., Darling, C.: ‘Transthoracic bioimpedance monitoring predicts heart failure decompensation and early readmission after heart failure hospitalization: preliminary data from SENTINEL-HF’, Circ., Cardiovasc. Qual. Outcomes, 2014, 319, (7), pp. 14.
    9. 9)
      • 5. Piskulak, P., Cybulski, G., Niewiadomski, W., Pałko, T.: ‘Computer program for automatic identification of artifacts in impedance cardiography signals recorded during ambulatory hemodynamic monitoring’. Proc. of XIIIMediterranean Conf. on Medical and Biological Engineering and Computing, Seville, Spain, September 2014, Vol. 41, pp. 766769, doi: 10.1007/978-3-319-00846-2-190.
    10. 10)
    11. 11)
    12. 12)
http://iet.metastore.ingenta.com/content/journals/10.1049/el.2014.4456
Loading

Related content

content/journals/10.1049/el.2014.4456
pub_keyword,iet_inspecKeyword,pub_concept
6
6
Loading